| Industrial Cables | |||
Industrial Cables
Flexible Control and Flexible Power Cable (600 Volt )
PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable
Applications:
Any continuous flexing application requiring a small diameter flexible cable
ROBOTS
Machine tools
Car body and vehicle assembly
Material handling equipment
Power tracks
Features:
Rated at 90°C
Extremely flexible with long flex life
Small diameter
Thermoset rubber jacket
Oil resistant
Suitable for indoor and outdoor applications
Meets cold bend test at -40°C
Construction:
Conductor:
18 AWG thru 12 AWG fully annealed stranded bare copper per ASTM B3
Class M: 18 AWG thru 16 AWG
Class K: 14 AWG thru 12 AWG
Stranding per ASTM B8
Insulation:
Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)
Color-Coded:
All conductors red, except #2 is white and #3 is green, all with alpha-numeric designations
Jacket:
Lead-Free Hypalon Chlorosulfonated Polyethylene (CSPE)/Elastomer blend
Approvals:
Industry Compliances:
UL Type TC / CSA AWM
Flame Tests Compliances:
IEEE 1202 (70,000 BTU/hr) CSA FT4
IEEE 383 (70,000 BTU/hr)
Other Compliances:
Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
OSHA acceptable
Product Parameter
AWG Size |
No. of Cond. |
Conductor Stranding |
Nom. Insul. Thick. (in) |
Jacket Thick |
Nom. O.D. (in) |
Min. Bend Radius |
Approx LBS/MFT |
18 |
6 |
41/34 |
0.02 |
0.045 |
0.39 |
3 |
93 |
18 |
8 |
41/34 |
0.02 |
0.045 |
0.455 |
3.5 |
116 |
18 |
12 |
41/34 |
0.02 |
0.045 |
0.49 |
4 |
155 |
18 |
16 |
41/34 |
0.02 |
0.06 |
0.57 |
4.5 |
211 |
18 |
22 |
41/34 |
0.02 |
0.06 |
0.65 |
5 |
272 |
16 |
6 |
65/34 |
0.02 |
0.045 |
0.43 |
3.5 |
122 |
16 |
8 |
65/34 |
0.02 |
0.045 |
0.49 |
3.9 |
152 |
16 |
12 |
65/34 |
0.02 |
0.06 |
0.575 |
4.5 |
216 |
16 |
16 |
65/34 |
0.02 |
0.06 |
0.63 |
5 |
277 |
16 |
22 |
65/34 |
0.02 |
0.06 |
0.725 |
5.5 |
368 |
14 |
6 |
41/30 |
0.02 |
0.045 |
0.46 |
3.7 |
159 |
14 |
8 |
41/30 |
0.02 |
0.06 |
0.56 |
4.5 |
219 |
14 |
12 |
41/30 |
0.02 |
0.06 |
0.67 |
5 |
295 |
14 |
16 |
41/30 |
0.02 |
0.06 |
0.68 |
5.5 |
375 |
14 |
22 |
41/30 |
0.02 |
0.06 |
0.785 |
6 |
495 |
12 |
6 |
65/30 |
0.02 |
0.06 |
0.555 |
4.5 |
238 |
12 |
8 |
65/30 |
0.02 |
0.06 |
0.635 |
5 |
300 |
12 |
12 |
65/30 |
0.02 |
0.06 |
0.705 |
5.5 |
433 |
12 |
16 |
65/30 |
0.02 |
0.06 |
0.78 |
6 |
535 |
12 |
22 |
65/30 |
0.02 |
0.08 |
0.945 |
7.5 |
789 |
PVC/Nylon/Neoprene Thermoset Flexible Control Cable
Applications:
Tight installations
Trays, conduits and raceways
Cranes and hoists
Pendant stations
Load lifts and platforms
Recommended for moderate flex applications
Features:
Rated at 90°C
Moderate flex cable
Small diameter
Thermoset rubber jacket
Flame retardant
Suitable for indoor and outdoor applications
Meets cold bend test at -40°C
Construction:
Conductor:
18 AWG thru 12 AWG fully annealed stranded bare copper per ASTM B3
Stranding per ASTM B8
Insulation:
Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)
Color-Coded: per ICEA method 1:
Table E-2 (Does not include white or green)
Jacket:
Thermosetting Neoprene
Approvals:
Industry Compliances:
UL Type TC - 600V
Flame Tests Compliances:
IEEE 1202 (70,000 BTU/hr)
IEEE 383 (70,000 BTU/hr)
Other Compliances:
Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
OSHA acceptable
Product Parameter
AWG Size |
No. of Cond. |
Conductor Stranding |
Nom. Insul. Thick. (in) |
Jacket Thick |
Approx LBS/MFT |
Nom. O.D. (in) |
Min. Bend Radius |
18 |
4 |
19/0.0092 |
0.02 |
0.045 |
65 |
0.31 |
2.5 |
18 |
8 |
19/0.0092 |
0.02 |
0.045 |
116 |
0.42 |
3.3 |
18 |
10 |
19/0.0092 |
0.02 |
0.045 |
135 |
0.45 |
3.6 |
18 |
12 |
19/0.0092 |
0.02 |
0.045 |
137 |
0.465 |
3.7 |
18 |
16 |
19/0.0092 |
0.02 |
0.045 |
175 |
0.515 |
4.1 |
18 |
19 |
19/0.0092 |
0.02 |
0.06 |
192 |
0.57 |
4.6 |
18 |
24 |
19/0.0092 |
0.02 |
0.06 |
297 |
0.66 |
5.3 |
18 |
30 |
19/0.0092 |
0.02 |
0.06 |
345 |
0.695 |
5.6 |
16 |
4 |
19/0.0117 |
0.02 |
0.045 |
85 |
0.345 |
2.8 |
16 |
8 |
19/0.0117 |
0.02 |
0.045 |
153 |
0.465 |
3.7 |
16 |
10 |
19/0.0117 |
0.02 |
0.045 |
179 |
0.5 |
4 |
16 |
12 |
19/0.0117 |
0.02 |
0.045 |
186 |
0.52 |
4.2 |
16 |
16 |
19/0.0117 |
0.02 |
0.045 |
257 |
0.605 |
4.8 |
16 |
19 |
19/0.0117 |
0.02 |
0.06 |
320 |
0.635 |
5.1 |
16 |
24 |
19/0.0117 |
0.02 |
0.06 |
403 |
0.735 |
5.9 |
16 |
30 |
19/0.0117 |
0.02 |
0.06 |
476 |
0.775 |
6.2 |
14 |
4 |
19/0.0147 |
0.02 |
0.045 |
117 |
0.375 |
3 |
14 |
8 |
19/0.0147 |
0.02 |
0.045 |
181 |
0.485 |
3.9 |
14 |
10 |
19/0.0147 |
0.02 |
0.06 |
270 |
0.595 |
4.8 |
14 |
12 |
19/0.0147 |
0.02 |
0.06 |
278 |
0.615 |
4.9 |
14 |
16 |
19/0.0147 |
0.02 |
0.06 |
353 |
0.675 |
5.4 |
14 |
19 |
19/0.0147 |
0.02 |
0.06 |
449 |
0.71 |
5.7 |
14 |
24 |
19/0.0147 |
0.02 |
0.06 |
565 |
0.825 |
6.6 |
14 |
30 |
19/0.0147 |
0.02 |
0.08 |
727 |
0.92 |
7.4 |
12 |
4 |
19/0.0185 |
0.02 |
0.045 |
157 |
0.42 |
304 |
12 |
8 |
19/0.0185 |
0.02 |
0.06 |
272 |
0.575 |
4.6 |
12 |
10 |
19/0.0185 |
0.02 |
0.06 |
369 |
0.67 |
5 |
12 |
12 |
19/0.0185 |
0.02 |
0.06 |
389 |
0.69 |
5.5 |
12 |
16 |
19/0.0185 |
0.02 |
0.06 |
503 |
0.765 |
6.1 |
12 |
19 |
19/0.0185 |
0.02 |
0.06 |
638 |
0.805 |
6.5 |
12 |
24 |
19/0.0185 |
0.02 |
0.08 |
841 |
0.98 |
7.8 |
12 |
30 |
19/0.0185 |
0.02 |
0.08 |
1017 |
1.04 |
8.3 |
PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable
Applications:
Any continuous flexing application requiring a small diameter flexible cable
ROBOTS
Machine tools
Car body and vehicle assembly
Plant automation equipment
Flexible cable tracks
PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable Features:
Rated at 90°C dry, 75°C wet
Flame retardant
Small diameter
Oil resistant
Thermoset rubber jacket
Meets cold bend test at -25°C
Construction:
Conductor:
16 AWG fully annealed stranded bare copper per ASTM B3
Class M stranding per ASTM B8
Insulation:
Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)
Color-Coded:
All conductors red, except #2 is white, the last conductor in each construction is green/yellow. All with alpha-numeric designations.
Jacket:
Thermosetting Nitrile/Polyvinyl Chloride (PVC)
Approvals:
Industry Compliances:
UL Type TC/CSA AWM
Flame Tests Compliances:
IEEE 1202 (70,000 BTU/hr)
IEEE 383 (70,000 BTU/hr)
Other Compliances:
Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
OSHA acceptable
Product Parameter
AWG Size |
No. of Cond. |
Conductor Stranding |
Nom. Insul. Thick. (in) |
Jacket Thick |
Approx LBS/MFT |
Nom. O.D. (in) |
Min. Bend Radius |
16 |
11 |
65/34 |
0.02 |
0.06 |
190 |
0.58 |
4.5 |
16 |
12 |
65/34 |
0.02 |
0.06 |
195 |
0.58 |
4.5 |
16 |
16 |
65/34 |
0.02 |
0.06 |
251 |
0.635 |
5 |
16 |
17 |
65/34 |
0.02 |
0.06 |
275 |
0.67 |
5.25 |
16 |
19 |
65/34 |
0.02 |
0.06 |
304 |
0.705 |
5.5 |
16 |
21 |
65/34 |
0.02 |
0.06 |
339 |
0.77 |
6 |
16 |
22 |
65/34 |
0.02 |
0.06 |
346 |
0.77 |
6 |
16 |
25 |
65/34 |
0.02 |
0.06 |
401 |
0.815 |
6.5 |
16 |
31 |
65/34 |
0.02 |
0.08 |
483 |
0.89 |
7 |
16 |
33 |
65/34 |
0.02 |
0.08 |
506 |
0.89 |
7 |
16 |
41 |
65/34 |
0.02 |
0.08 |
622 |
0.975 |
7.75 |
16 |
42 |
65/34 |
0.02 |
0.08 |
629 |
0.975 |
7.75 |
16 |
47 |
65/34 |
0.02 |
0.08 |
684 |
1.025 |
8.25 |
16 |
49 |
65/34 |
0.02 |
0.08 |
724 |
1.055 |
8.5 |
16 |
60 |
65/34 |
0.02 |
0.08 |
851 |
1.125 |
9 |
16 |
65 |
65/34 |
0.02 |
0.08 |
927 |
1.18 |
9.5 |
PVC/Nylon/PVC Thermoplastic Flexible Control Cable
Applications:
Pendant cable
Machine tool
Internal machine connections
Material handling equipment
Moderate flex
Features:
Rated at 90°C
Moisture and oil resistant
Heavy-duty PVC jacket
Meets cold bend test at -25°C
Construction:
Conductor:
18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3
Class M: 18 AWG thru 16 AWG
Class K: 14 AWG thru 10 AW
Stranding per ASTM B8
Insulation:
Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)
Color-Coded:
All conductors red, except #2 is white and #3 is green. All with alpha-numeric designations.
Jacket:
Heat, moisture and oil resistant Polyvinyl Chloride (PVC)
Approvals:
Industry Compliances:
UL Type MTW/CSA AWM
Other Compliances:
Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
OSHA acceptable
RoHS compliant
Product Parameter
AWG Size |
No. of Cond. |
Conductor Stranding |
Nom. Insul. Thick. (in) |
Jacket Thick |
Approx LBS/MFT |
Nom. O.D. (in) |
Min. Bend Radius |
18 |
6 |
41/34 |
0.02 |
0.045 |
88 |
0.4 |
3 |
18 |
8 |
41/34 |
0.02 |
0.045 |
108 |
0.455 |
3.5 |
18 |
12 |
41/34 |
0.02 |
0.045 |
144 |
0.5 |
4 |
18 |
16 |
41/34 |
0.02 |
0.06 |
196 |
0.58 |
4.5 |
18 |
22 |
41/34 |
0.02 |
0.06 |
252 |
0.66 |
5 |
18 |
31 |
41/34 |
0.02 |
0.06 |
325 |
0.76 |
6 |
18 |
41 |
41/34 |
0.02 |
0.08 |
460 |
0.89 |
7 |
18 |
60 |
41/34 |
0.02 |
0.08 |
617 |
1.01 |
8 |
16 |
6 |
65/34 |
0.02 |
0.045 |
113 |
0.44 |
3.5 |
16 |
8 |
65/34 |
0.02 |
0.045 |
141 |
0.5 |
4 |
16 |
12 |
65/34 |
0.02 |
0.06 |
214 |
0.585 |
4.5 |
16 |
16 |
65/34 |
0.02 |
0.06 |
263 |
0.64 |
5 |
16 |
22 |
65/34 |
0.02 |
0.06 |
377 |
0.735 |
5.5 |
16 |
31 |
65/34 |
0.02 |
0.06 |
518 |
0.845 |
6.5 |
16 |
41 |
65/34 |
0.02 |
0.08 |
652 |
0.995 |
8 |
16 |
60 |
65/34 |
0.02 |
0.08 |
909 |
1.125 |
9 |
14 |
6 |
41/30 |
0.02 |
0.045 |
149 |
0.47 |
3.5 |
14 |
8 |
41/30 |
0.02 |
0.06 |
204 |
0.57 |
4.5 |
14 |
12 |
41/30 |
0.02 |
0.06 |
279 |
0.63 |
5 |
14 |
16 |
41/30 |
0.02 |
0.06 |
354 |
0.69 |
5.5 |
14 |
22 |
41/30 |
0.02 |
0.06 |
467 |
0.795 |
6 |
12 |
6 |
65/30 |
0.02 |
0.06 |
226 |
0.565 |
4.5 |
12 |
8 |
65/30 |
0.02 |
0.06 |
289 |
0.645 |
5 |
12 |
12 |
65/30 |
0.02 |
0.06 |
398 |
0.715 |
5.5 |
12 |
16 |
65/30 |
0.02 |
0.06 |
506 |
0.79 |
6 |
12 |
22 |
65/30 |
0.02 |
0.08 |
720 |
0.955 |
7.5 |
10 |
6 |
105/30 |
0.026 |
0.06 |
329 |
0.665 |
5 |
10 |
8 |
105/30 |
0.026 |
0.06 |
424 |
0.765 |
6 |
10 |
12 |
105/30 |
0.026 |
0.08 |
604 |
0.895 |
7 |
10 |
16 |
105/30 |
0.026 |
0.08 |
852 |
1.155 |
9 |
PVC/PVC Thermoplastic Festoon Control Cable
Applications:
Cranes and hoists
Festooning systems
Track systems
ROBOTS
Conveyors
Telescoping jetways
Features:
Rated at 105°C
Designed for continuous extreme flexing applications
Anti-coiling in festoon applications
Small bending radii
Flat construction allows for stacking
Oil and chemical resistant
Indoor or outdoor use
Meets cold bend test at -55°C
Construction:
Conductor:
16 AWG thru 2 AWG fully annealed stranded bare copper per ASTM B3
Class M: 16 AWG
Class K: 14 AWG thru 2 AW
Stranding per ASTM B8
Insulation:
Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon)
Color-Coded: per ICEA Method 1:
Table E-2 (does not include white or green) All with alpha-numeric designations.
Jacket:
Flame retardant Polyvinyl Chloride (PVC) - yellow or black
Approvals:
Industry Compliances:
UL Listed/CSA certified flat festoon cable
Flame Tests Compliances:
UL VW-1/CSA FT1
Other Compliances:
Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method
OSHA acceptable
AWG Size |
No. of Cond. |
Conductor Stranding |
Nom. Insul. Thick. (in) |
Jacket Thick |
Approx Dimension |
Approx LBS/MFT |
16 |
4 |
65/34 |
0.03 |
0.035 |
.200 x .580 |
91 |
16 |
8 |
65/34 |
0.03 |
0.035 |
.200 x 1.110 |
173 |
16 |
12 |
65/34 |
0.03 |
0.035 |
.200 x 1.605 |
253 |
14 |
4 |
41/30 |
0.03 |
0.035 |
.210 x .710 |
116 |
14 |
8 |
41/30 |
0.03 |
0.035 |
.210 x 1.175 |
224 |
14 |
12 |
41/30 |
0.03 |
0.035 |
.210 x 1.700 |
330 |
12 |
4 |
65/30 |
0.03 |
0.035 |
.230 x .710 |
160 |
12 |
5 |
65/30 |
0.03 |
0.035 |
.230 x .865 |
195 |
12 |
7 |
65/30 |
0.03 |
0.035 |
.230 x 1.340 |
271 |
12 |
8 |
65/30 |
0.03 |
0.035 |
.230 x 1.650 |
307 |
10 |
4 |
105/30 |
0.03 |
0.045 |
.270 x .880 |
241 |
8 |
4 |
168/30 |
0.045 |
0.045 |
.365 x 1.190 |
405 |
6 |
4 |
266/30 |
0.06 |
0.045 |
.430 x 1.450 |
612 |
6 |
5 |
266/30 |
0.06 |
0.045 |
.430 x 1.735 |
747 |
4 |
4 |
420/30 |
0.06 |
0.045 |
.490 x 1.690 |
750 |
2 |
4 |
665/30 |
0.06 |
0.045 |
.560 x 1.955 |
1273 |