中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Industrial Cables  

Industrial PVC Insulated Cables

Industrial XLPE

 Insulated Cables

Industrial EPR

 Insulated Cables

Industrial Rubber

Insulated Cables

Industrial

Twinax Cables

Industrial 

Data Cables

Industrial 

Coaxial Cables

Industrial Optical

Fiber Cables

 

Industrial Cables

Flexible Control and Flexible Power Cable (600 Volt ) 

PVC/Nylon/HYP Thermoset Continuous Flexing Control Cable 

Applications:

Any continuous flexing application requiring a small diameter flexible cable 

ROBOTS 

Machine tools 

Car body and vehicle assembly 

Material handling equipment 

Power tracks

Features:

Rated at 90°C 

Extremely flexible with long flex life 

Small diameter 

Thermoset rubber jacket 

Oil resistant 

Suitable for indoor and outdoor applications 

Meets cold bend test at -40°C

Construction: 

Conductor: 

18 AWG thru 12 AWG fully annealed stranded bare copper per ASTM B3 

Class M: 18 AWG thru 16 AWG 

Class K: 14 AWG thru 12 AWG 

Stranding per ASTM B8

Insulation: 

Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon) 

Color-Coded: 

All conductors red, except #2 is white and #3 is green, all with alpha-numeric designations

Jacket: 

Lead-Free Hypalon Chlorosulfonated Polyethylene (CSPE)/Elastomer blend

Approvals: 

Industry Compliances: 

UL Type TC / CSA AWM

Flame Tests Compliances: 

IEEE 1202 (70,000 BTU/hr) CSA FT4 

IEEE 383 (70,000 BTU/hr)

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

No. of Cond.

Conductor Stranding

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. (in)

Min. Bend Radius

Approx LBS/MFT

18

6

41/34

0.02

0.045

0.39

3

93

18

8

41/34

0.02

0.045

0.455

3.5

116

18

12

41/34

0.02

0.045

0.49

4

155

18

16

41/34

0.02

0.06

0.57

4.5

211

18

22

41/34

0.02

0.06

0.65

5

272

16

6

65/34

0.02

0.045

0.43

3.5

122

16

8

65/34

0.02

0.045

0.49

3.9

152

16

12

65/34

0.02

0.06

0.575

4.5

216

16

16

65/34

0.02

0.06

0.63

5

277

16

22

65/34

0.02

0.06

0.725

5.5

368

14

6

41/30

0.02

0.045

0.46

3.7

159

14

8

41/30

0.02

0.06

0.56

4.5

219

14

12

41/30

0.02

0.06

0.67

5

295

14

16

41/30

0.02

0.06

0.68

5.5

375

14

22

41/30

0.02

0.06

0.785

6

495

12

6

65/30

0.02

0.06

0.555

4.5

238

12

8

65/30

0.02

0.06

0.635

5

300

12

12

65/30

0.02

0.06

0.705

5.5

433

12

16

65/30

0.02

0.06

0.78

6

535

12

22

65/30

0.02

0.08

0.945

7.5

789

PVC/Nylon/Neoprene Thermoset Flexible Control Cable 

Applications:

Tight installations 

Trays, conduits and raceways 

Cranes and hoists 

Pendant stations 

Load lifts and platforms 

Recommended for moderate flex applications

Features:

Rated at 90°C 

Moderate flex cable 

Small diameter 

Thermoset rubber jacket 

Flame retardant 

Suitable for indoor and outdoor applications 

Meets cold bend test at -40°C

Construction: 

Conductor: 

18 AWG thru 12 AWG fully annealed stranded bare copper per ASTM B3 

Stranding per ASTM B8

Insulation: 

Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon) 

Color-Coded: per ICEA method 1: 

Table E-2 (Does not include white or green)

Jacket: 

Thermosetting Neoprene

Approvals: 

Industry Compliances: 

UL Type TC - 600V

Flame Tests Compliances: 

IEEE 1202 (70,000 BTU/hr) 

IEEE 383 (70,000 BTU/hr)

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

No. of Cond.

Conductor Stranding

Nom. Insul. Thick. (in)

Jacket Thick

Approx LBS/MFT

Nom. O.D. (in)

Min. Bend Radius

18

4

19/0.0092

0.02

0.045

65

0.31

2.5

18

8

19/0.0092

0.02

0.045

116

0.42

3.3

18

10

19/0.0092

0.02

0.045

135

0.45

3.6

18

12

19/0.0092

0.02

0.045

137

0.465

3.7

18

16

19/0.0092

0.02

0.045

175

0.515

4.1

18

19

19/0.0092

0.02

0.06

192

0.57

4.6

18

24

19/0.0092

0.02

0.06

297

0.66

5.3

18

30

19/0.0092

0.02

0.06

345

0.695

5.6

16

4

19/0.0117

0.02

0.045

85

0.345

2.8

16

8

19/0.0117

0.02

0.045

153

0.465

3.7

16

10

19/0.0117

0.02

0.045

179

0.5

4

16

12

19/0.0117

0.02

0.045

186

0.52

4.2

16

16

19/0.0117

0.02

0.045

257

0.605

4.8

16

19

19/0.0117

0.02

0.06

320

0.635

5.1

16

24

19/0.0117

0.02

0.06

403

0.735

5.9

16

30

19/0.0117

0.02

0.06

476

0.775

6.2

14

4

19/0.0147

0.02

0.045

117

0.375

3

14

8

19/0.0147

0.02

0.045

181

0.485

3.9

14

10

19/0.0147

0.02

0.06

270

0.595

4.8

14

12

19/0.0147

0.02

0.06

278

0.615

4.9

14

16

19/0.0147

0.02

0.06

353

0.675

5.4

14

19

19/0.0147

0.02

0.06

449

0.71

5.7

14

24

19/0.0147

0.02

0.06

565

0.825

6.6

14

30

19/0.0147

0.02

0.08

727

0.92

7.4

12

4

19/0.0185

0.02

0.045

157

0.42

304

12

8

19/0.0185

0.02

0.06

272

0.575

4.6

12

10

19/0.0185

0.02

0.06

369

0.67

5

12

12

19/0.0185

0.02

0.06

389

0.69

5.5

12

16

19/0.0185

0.02

0.06

503

0.765

6.1

12

19

19/0.0185

0.02

0.06

638

0.805

6.5

12

24

19/0.0185

0.02

0.08

841

0.98

7.8

12

30

19/0.0185

0.02

0.08

1017

1.04

8.3

PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable 

Applications:

Any continuous flexing application requiring a small diameter flexible cable 

ROBOTS 

Machine tools 

Car body and vehicle assembly 

Plant automation equipment 

Flexible cable tracks

PVC/Nylon/Nitrile/PVC Thermoset Continuous Flexing Control Cable Features:

Rated at 90°C dry, 75°C wet 

Flame retardant 

Small diameter 

Oil resistant 

Thermoset rubber jacket 

Meets cold bend test at -25°C

Construction: 

Conductor: 

16 AWG fully annealed stranded bare copper per ASTM B3 

Class M stranding per ASTM B8

Insulation: 

Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon) 

Color-Coded: 

All conductors red, except #2 is white, the last conductor in each construction is green/yellow. All with alpha-numeric designations.

Jacket: 

Thermosetting Nitrile/Polyvinyl Chloride (PVC)

Approvals: 

Industry Compliances: 

UL Type TC/CSA AWM

Flame Tests Compliances: 

IEEE 1202 (70,000 BTU/hr) 

IEEE 383 (70,000 BTU/hr)

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

No. of Cond.

Conductor Stranding

Nom. Insul. Thick. (in)

Jacket Thick

Approx LBS/MFT

Nom. O.D. (in)

Min. Bend Radius

16

11

65/34

0.02

0.06

190

0.58

4.5

16

12

65/34

0.02

0.06

195

0.58

4.5

16

16

65/34

0.02

0.06

251

0.635

5

16

17

65/34

0.02

0.06

275

0.67

5.25

16

19

65/34

0.02

0.06

304

0.705

5.5

16

21

65/34

0.02

0.06

339

0.77

6

16

22

65/34

0.02

0.06

346

0.77

6

16

25

65/34

0.02

0.06

401

0.815

6.5

16

31

65/34

0.02

0.08

483

0.89

7

16

33

65/34

0.02

0.08

506

0.89

7

16

41

65/34

0.02

0.08

622

0.975

7.75

16

42

65/34

0.02

0.08

629

0.975

7.75

16

47

65/34

0.02

0.08

684

1.025

8.25

16

49

65/34

0.02

0.08

724

1.055

8.5

16

60

65/34

0.02

0.08

851

1.125

9

16

65

65/34

0.02

0.08

927

1.18

9.5

PVC/Nylon/PVC Thermoplastic Flexible Control Cable 

Applications:

Pendant cable 

Machine tool 

Internal machine connections 

Material handling equipment 

Moderate flex

Features:

Rated at 90°C 

Moisture and oil resistant 

Heavy-duty PVC jacket 

Meets cold bend test at -25°C

Construction: 

Conductor: 

18 AWG thru 10 AWG fully annealed stranded bare copper per ASTM B3 

Class M: 18 AWG thru 16 AWG 

Class K: 14 AWG thru 10 AW 

Stranding per ASTM B8

Insulation: 

Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon) 

Color-Coded: 

All conductors red, except #2 is white and #3 is green. All with alpha-numeric designations.

Jacket: 

Heat, moisture and oil resistant Polyvinyl Chloride (PVC)

Approvals: 

Industry Compliances: 

UL Type MTW/CSA AWM

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable 

RoHS compliant

Product Parameter

AWG Size

No. of Cond.

Conductor Stranding

Nom. Insul. Thick. (in)

Jacket Thick

Approx LBS/MFT

Nom. O.D. (in)

Min. Bend Radius

18

6

41/34

0.02

0.045

88

0.4

3

18

8

41/34

0.02

0.045

108

0.455

3.5

18

12

41/34

0.02

0.045

144

0.5

4

18

16

41/34

0.02

0.06

196

0.58

4.5

18

22

41/34

0.02

0.06

252

0.66

5

18

31

41/34

0.02

0.06

325

0.76

6

18

41

41/34

0.02

0.08

460

0.89

7

18

60

41/34

0.02

0.08

617

1.01

8

16

6

65/34

0.02

0.045

113

0.44

3.5

16

8

65/34

0.02

0.045

141

0.5

4

16

12

65/34

0.02

0.06

214

0.585

4.5

16

16

65/34

0.02

0.06

263

0.64

5

16

22

65/34

0.02

0.06

377

0.735

5.5

16

31

65/34

0.02

0.06

518

0.845

6.5

16

41

65/34

0.02

0.08

652

0.995

8

16

60

65/34

0.02

0.08

909

1.125

9

14

6

41/30

0.02

0.045

149

0.47

3.5

14

8

41/30

0.02

0.06

204

0.57

4.5

14

12

41/30

0.02

0.06

279

0.63

5

14

16

41/30

0.02

0.06

354

0.69

5.5

14

22

41/30

0.02

0.06

467

0.795

6

12

6

65/30

0.02

0.06

226

0.565

4.5

12

8

65/30

0.02

0.06

289

0.645

5

12

12

65/30

0.02

0.06

398

0.715

5.5

12

16

65/30

0.02

0.06

506

0.79

6

12

22

65/30

0.02

0.08

720

0.955

7.5

10

6

105/30

0.026

0.06

329

0.665

5

10

8

105/30

0.026

0.06

424

0.765

6

10

12

105/30

0.026

0.08

604

0.895

7

10

16

105/30

0.026

0.08

852

1.155

9

PVC/PVC Thermoplastic Festoon Control Cable 

Applications:

Cranes and hoists 

Festooning systems 

Track systems 

ROBOTS 

Conveyors 

Telescoping jetways

Features:

Rated at 105°C 

Designed for continuous extreme flexing applications 

Anti-coiling in festoon applications 

Small bending radii 

Flat construction allows for stacking 

Oil and chemical resistant 

Indoor or outdoor use 

Meets cold bend test at -55°C

Construction: 

Conductor: 

16 AWG thru 2 AWG fully annealed stranded bare copper per ASTM B3 

Class M: 16 AWG 

Class K: 14 AWG thru 2 AW 

Stranding per ASTM B8

Insulation: 

Flame-retardant Polyvinyl Chloride (PVC) with clear Polyamide (nylon) 

Color-Coded: per ICEA Method 1: 

Table E-2 (does not include white or green) All with alpha-numeric designations.

Jacket: 

Flame retardant Polyvinyl Chloride (PVC) - yellow or black

Approvals: 

Industry Compliances: 

UL Listed/CSA certified flat festoon cable

Flame Tests Compliances: 

UL VW-1/CSA FT1

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

No. of Cond.

Conductor Stranding

Nom. Insul. Thick. (in)

Jacket Thick

Approx Dimension

Approx LBS/MFT

16

4

65/34

0.03

0.035

.200 x .580

91

16

8

65/34

0.03

0.035

.200 x 1.110

173

16

12

65/34

0.03

0.035

.200 x 1.605

253

14

4

41/30

0.03

0.035

.210 x .710

116

14

8

41/30

0.03

0.035

.210 x 1.175

224

14

12

41/30

0.03

0.035

.210 x 1.700

330

12

4

65/30

0.03

0.035

.230 x .710

160

12

5

65/30

0.03

0.035

.230 x .865

195

12

7

65/30

0.03

0.035

.230 x 1.340

271

12

8

65/30

0.03

0.035

.230 x 1.650

307

10

4

105/30

0.03

0.045

.270 x .880

241

8

4

168/30

0.045

0.045

.365 x 1.190

405

6

4

266/30

0.06

0.045

.430 x 1.450

612

6

5

266/30

0.06

0.045

.430 x 1.735

747

4

4

420/30

0.06

0.045

.490 x 1.690

750

2

4

665/30

0.06

0.045

.560 x 1.955

1273

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com