中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Industrial Cables  

Industrial PVC Insulated Cables

Industrial XLPE

 Insulated Cables

Industrial EPR

 Insulated Cables

Industrial Rubber

Insulated Cables

Industrial

Twinax Cables

Industrial 

Data Cables

Industrial 

Coaxial Cables

Industrial Optical

Fiber Cables

 

Industrial Cables

Industrial PVC Insulated Cables

Instrumentation Cable (300 Volt) 

PVC/PVC Instrumentation Cable with Overall Shielded Pairs/Triads 

Applications:

Acceptable for use in free air or raceways in accordance with NEC 

Typical applications include audio, intercom, control, energy management and alarm circuits. 

In ducts, cable trays or conduit 

In accordance with UL Subject 13 as Power-Limited Circuit Cable 

In class 3 circuits in accordance with NEC 

In accordance with UL subject 2250 as Instrumentation Tray Cable (ITC) 

Permitted for use in Class 1 Division 2 industrial hazardous locations per NEC Article 501-4(b) for UL Type PLTC/ITC cables 

Per NEC Article 727 for Type PLTC/ITC

Construction:

Conductor: 20 AWG thru 16 AWG bare, annealed copper per ASTM B3 ,Class B stranding per ASTM B8

Insulation: Polyvinyl Chloride (PVC) ,Color-coded per ICEA Method 1: 

Pairs: Black and White 

Triads: Black, White and Red

Shield: Overall shielded pairs/triads ,Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: Flame-retardant and sunlight-resistant Polyvinyl Chloride (PVC)

Options: Tinned copper conductor; Class C Stranding; Other constructions available upon request

Approvals:

Industry Compliances: 

UL 13 Type PLTC/ITC

Flame Tests Compliances: 

IEEE 383 (70,000 BTU/hr) 

UL Subject 13 (70,000 BTU/hr) for PLTC 

UL Subject 2250 (70,000 BTU/hr) for ITC

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

Conductor Stranding

No. of Pairs

No. of Triads

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. of Cable (in)

Approx LBS/MFT

20

7/0.0121

1

 

0.012

0.04

0.22

28

20

7/0.0121

 

1

0.012

0.04

0.241

34

20

7/0.0121

2

 

0.012

0.04

0.255

41

20

7/0.0121

4

 

0.012

0.042

0.321

65

20

7/0.0121

8

 

0.012

0.05

0.475

104

20

7/0.0121

12

 

0.012

0.05

0.545

195

20

7/0.0121

16

 

0.012

0.05

0.605

248

20

7/0.0121

20

 

0.012

0.06

0.65

309

20

7/0.0121

24

 

0.012

0.06

0.74

376

20

7/0.0121

36

 

0.012

0.06

0.85

530

20

7/0.0121

50

 

0.012

0.07

0.97

713

18

7/0.0152

1

 

0.015

0.04

0.24

35

18

7/0.0152

 

1

0.015

0.04

0.264

44

18

7/0.0152

2

 

0.015

0.042

0.325

55

18

7/0.0152

4

 

0.015

0.042

0.357

90

18

7/0.0152

8

 

0.015

0.06

0.646

192

18

7/0.0152

12

 

0.015

0.06

0.67

293

18

7/0.0152

16

 

0.015

0.06

0.75

374

18

7/0.0152

20

 

0.015

0.06

0.78

449

18

7/0.0152

24

 

0.015

0.07

0.915

564

18

7/0.0152

36

 

0.015

0.07

1.03

787

18

7/0.0152

50

 

0.015

0.07

1.18

1059

16

7/0.0192

1

 

0.015

0.04

0.273

45

16

7/0.0192

 

1

0.015

0.042

0.297

58

16

7/0.0192

2

 

0.015

0.042

0.344

74

16

7/0.0192

4

 

0.015

0.053

0.481

132

16

7/0.0192

8

 

0.015

0.06

0.726

259

16

7/0.0192

12

 

0.015

0.06

0.755

408

16

7/0.0192

16

 

0.015

0.07

0.845

526

16

7/0.0192

20

 

0.015

0.07

0.905

655

16

7/0.0192

24

 

0.015

0.07

1.03

803

16

7/0.0192

36

 

0.015

0.07

1.165

1122

16

7/0.0192

50

 

0.015

0.08

1.355

1544

PVC/PVC Instrumentation Cable with Individual and Overall Shielded Pairs 

Applications

Acceptable for use in free air or raceways in accordance with NEC 

Typical applications include audio, intercom, control, energy management and alarm circuits. 

In ducts, cable trays or conduit 

In accordance with UL Subject 13 as Power-Limited Circuit Cable 

In class 3 circuits in accordance with NEC 

In accordance with UL subject 2250 as Instrumentation Tray Cable (ITC) 

Permitted for use in Class 1 Division 2 industrial hazardous locations per NEC Article 501-4(b) for UL Type PLTC/ITC cables 

Per NEC Article 727 for Type PLTC/ITC

Construction

Conductor: 

20 AWG thru 16 AWG bare, annealed copper per ASTM B3 

Class B stranding per ASTM B8

Insulation: 

Polyvinyl Chloride (PVC) 

Color-coded per ICEA Method 1: 

Pairs: Black and White

Shield: 

Individual and overall shielded pairs 

Individual pairs are 100% shielded with aluminum/polyester in contact with stranded tinned copper drain wire 

Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: 

Sunlight-resistant Polyvinyl Chloride (PVC)

Options: 

Tinned copper conductor 

Class C Stranding 

Other constructions available upon request

Approvals

Industry Compliances: 

UL 13 Type PLTC/ITC

Flame Tests Compliances: 

IEEE 383 (70,000 BTU/hr) 

UL Subject 13 (70,000 BTU/hr) for PLTC 

UL Subject 2250 (70,000 BTU/hr) for ITC

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

Conduct

or Stranding

No. of Pairs

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. of Cable (in)

Approx LBS/MFT

20

7/0.0121

2

0.012

0.04

0.316

46

20

7/0.0121

4

0.012

0.042

0.325

76

20

7/0.0121

8

0.012

0.05

0.426

148

20

7/0.0121

12

0.012

0.06

0.64

223

20

7/0.0121

16

0.012

0.06

0.705

280

20

7/0.0121

20

0.012

0.06

0.78

339

20

7/0.0121

24

0.012

0.06

0.845

397

20

7/0.0121

36

0.012

0.07

1.015

586

20

7/0.0121

50

0.012

0.07

1.19

786

18

7/0.0152

2

0.015

0.042

0.296

61

18

7/0.0152

4

0.015

0.042

0.41

100

18

7/0.0152

8

0.015

0.06

0.485

212

18

7/0.0152

12

0.015

0.06

0.76

315

18

7/0.0152

16

0.015

0.06

0.845

401

18

7/0.0152

20

0.015

0.07

0.955

505

18

7/0.0152

24

0.015

0.07

1.04

596

18

7/0.0152

36

0.015

0.07

1.215

846

18

7/0.0152

50

0.015

0.08

1.45

1165

16

7/0.0192

2

0.015

0.042

0.346

80

16

7/0.0192

4

0.015

0.053

0.506

151

16

7/0.0192

8

0.015

0.06

0.665

288

16

7/0.0192

12

0.015

0.06

0.855

435

16

7/0.0192

16

0.015

0.07

0.97

575

16

7/0.0192

20

0.015

0.07

1.08

705

16

7/0.0192

24

0.015

0.07

1.165

828

16

7/0.0192

36

0.015

0.08

1.39

1215

16

7/0.0192

50

0.015

0.09

1.655

1670

PVC/PVC Instrumentation Cable with Individual and Overall Shielded Triads 

Applications

Acceptable for use in free air or raceways in accordance with NEC 

Typical applications include audio, intercom, control, energy management and alarm circuits. 

In ducts, cable trays or conduit 

In accordance with UL Subject 13 as Power-Limited Circuit Cable 

In class 3 circuits in accordance with NEC 

In accordance with UL subject 2250 as Instrumentation Tray Cable (ITC) 

Permitted for use in Class 1 Division 2 industrial hazardous locations per NEC Article 501-4(b) for UL Type PLTC/ITC cables 

Per NEC Article 727 for Type PLTC/ITC

Construction

Conductor: 

20 AWG thru 16 AWG bare, annealed copper per ASTM B3 

Class B stranding per ASTM B8

Insulation: 

Polyvinyl Chloride (PVC) 

Color-coded per ICEA Method 1: 

Pairs: Black and White 

Triads: Black, White and Red

Shield: 

Individual and overall shielded triads 

Individual triads are 100% shielded with aluminum/polyester in contact with stranded tinned copper drain wire 

Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: 

Sunlight-resistant Polyvinyl Chloride (PVC)

Options: 

Tinned copper conductor 

Class C Stranding 

Other constructions available upon request

Approvals: 

Industry Compliances: 

UL 13 Type PLTC/ITC

Flame Tests Compliances: 

IEEE 383 (70,000 BTU/hr) 

UL Subject 13 (70,000 BTU/hr) for PLTC 

UL Subject 2250 (70,000 BTU/hr) for ITC

Other Compliances: 

Meets EPA 40 CFR, Part 261 for leachable lead content per TCLP method 

OSHA acceptable

Product Parameter

AWG Size

Conductor Stranding

No. of Triads

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. of Cable (in)

Approx LBS/MFT

20

7/0.0121

2

0.012

0.04

0.34

59

20

7/0.0121

4

0.012

0.04

0.365

97

20

7/0.0121

8

0.012

0.05

0.566

187

20

7/0.0121

12

0.012

0.06

0.705

287

20

7/0.0121

16

0.012

0.06

0.78

365

20

7/0.0121

20

0.012

0.06

0.86

440

20

7/0.0121

24

0.012

0.07

0.955

541

20

7/0.0121

36

0.012

0.07

1.115

767

18

7/0.0152

2

0.015

0.04

0.321

77

18

7/0.0152

4

0.015

0.05

0.444

143

18

7/0.0152

8

0.015

0.06

0.786

375

18

7/0.0152

12

0.015

0.06

0.84

412

18

7/0.0152

16

0.015

0.07

0.96

550

18

7/0.0152

20

0.015

0.07

1.06

668

18

7/0.0152

24

0.015

0.07

1.145

785

18

7/0.0152

36

0.015

0.08

1.365

1151

16

7/0.0192

2

0.015

0.04

0.367

104

16

7/0.0192

4

0.015

0.05

0.502

195

16

7/0.0192

8

0.015

0.06

0.786

375

16

7/0.0192

12

0.015

0.07

0.97

597

16

7/0.0192

16

0.015

0.07

1.075

765

16

7/0.0192

20

0.015

0.07

1.195

933

16

7/0.0192

24

0.015

0.08

1.31

1125

16

7/0.0192

36

0.015

0.08

1.54

1620