中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Industrial Cables  

Industrial PVC Insulated Cables

Industrial XLPE

 Insulated Cables

Industrial EPR

 Insulated Cables

Industrial Rubber

Insulated Cables

Industrial

Twinax Cables

Industrial 

Data Cables

Industrial 

Coaxial Cables

Industrial Optical

Fiber Cables

 

Industrial Cables

Instrumentation Cable (600 Volt) 

XLPE/HYP Instrumentation Cable with Individual and Overall Shielded Pairs/Triads 

Applications:

Typical applications include audio, intercom, control, energy management and alarm circuits. 

Acceptable for use in free air or raceways or direct burial 

In wet or dry locations 

Permitted for use in Class 1 Division 2 industrial hazardous locations per NEC 

XLPE/HYP Instrumentation Cable with Individual and Overall Shielded Pairs/Triads Features:

Rated at 90°C wet or dry 

Ripcord applied to all cables with jacket thickness of 60 mils or less 

Oil-resistant jacket 

Sunlight and weather resistant 

Excellent electrical, thermal, and physical properties 

Excellent moisture resistance 

Excellent flame resistance 

"Heavy duty" rating per ICEA standards 

Excellent low temperature cold bend characteristics 

Meets cold bend test at -35°C

Construction: 

Conductor: 

18 AWG and 16 AWC tinned, annealed copper per ASTM B33 

Class B stranding per ASTM B8

Insulation: 

Flame-retardnat Cross-linked Polyethylene (XLPE) 

Color-coded per ICEA Method 1: 

Pairs: Black and White 

Triads: Black, White and Red

Shield: 

Individual and Overall shielded pairs/triads is aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: 

Low-lead Hypalon Cholorsulfonated Polyethylene (CSPE)/Elastomer blend

Options: 

300V Type PLTC 

Bare copper conductor 

Class C Stranding 

EHTC®-Ethylene Propylene Rubber jacket 

Overall shielded pairs/traids 

Thermoplasic, Low-Smoke, Zero-Halogen (LSZH) jacket 

In accordance with UL subject 2250 as Instrumentation Tray Cable (ITC) 

Other constructions available upon request 

Approvals: 

Industry Compliances: 

UL Type RFH-2, FFH-2 conductors 

UL 1277 Type TC 

UL 1581 

ICEA S-82-552 

ICEA S-73-532

Flame Tests Compliances: 

UL 1581 VW-1 

UL 1277 

IEEE 383 

IEEE 1202 

CSA FT-4 

ICEA T-29-520

Other Compliances: 

EPA 40 CFR, Part 261 for leachable lead content per TCLP 

OSHA acceptable 

Product Parameter

AWG Size

Conductor Stranding

No. of Pairs

No. of Triads

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. of Cable (in)

Approx LBS/MFT

18

7/0.0152

1

0.03

0.045

0.315

49

18

7/0.0152

1

0.03

0.045

0.335

64

18

7/0.0152

2

0.03

0.045

0.51

92

18

7/0.0152

4

0.03

0.06

0.63

167

18

7/0.0152

8

0.03

0.08

0.855

326

18

7/0.0152

12

0.03

0.08

1.03

441

18

7/0.0152

16

0.03

0.08

1.14

554

18

7/0.0152

20

0.03

0.08

1.265

676

18

7/0.0152

24

0.03

0.08

1.45

795

18

7/0.0152

36

0.03

0.11

1.65

1118

18

7/0.0152

50

0.03

0.11

2.085

1616

16

7/0.0192

1

0.03

0.045

0.345

61

16

7/0.0192

1

0.03

0.045

0.36

85

16

7/0.0192

2

0.03

0.06

0.585

130

16

7/0.0192

4

0.03

0.06

0.675

204

16

7/0.0192

8

0.03

0.08

0.915

394

16

7/0.0192

12

0.03

0.08

1.11

548

16

7/0.0192

16

0.03

0.08

1.35

713

16

7/0.0192

20

0.03

0.08

1.365

850

16

7/0.0192

24

0.03

0.08

1.57

1001

16

7/0.0192

36

0.03

0.11

1.98

1548

16

7/0.0192

50

0.03

0.11

2.165

2020

XLPE/Arctic-Grade PVC Instrumentation Cable with Overall Shielded Pairs/Triads 

Applications:

Typical applications include industrial lighting, control and signaling circuits. 

Primary installations cable trays, raceways or outdoor applications where supported by messenger wire 

In wet or dry locations 

XLPE/Arctic-Grade PVC Instrumentation Cable with Overall Shielded Pairs/Triads Features:

Rated at 90°C wet or dry 

Ripcord applied to all cables with jacket thickness of 60 mils or less 

Sunlight and weather resistant 

Meets CSA cold impact test at -40°C 

Meets ICEA and CSA cold bend test at -65°C

Construction: 

Conductor: 

18 AWG and 16 AWC tinned, annealed copper per ASTM B33 

Class B stranding per ASTM B8

Insulation: 

Flame-retardant Cross-Linked Polyethylene (XLPE) 

Color-coded per ICEA Method 1: 

Pairs: Black and White 

Triads: Black, White and Red

Shield: 

Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: 

Flame-retardant and sunlight-resistant Arctic-grade Polyvinyl Chloride (PVC)

Options: 

Bare copper conductor 

Class C Stranding 

E-2 Color Code 

CSA Rated TC for 14 AWG and larger 

Other constructions available upon request 

Approvals: 

Industry Compliances: 

UL 1277 Type TC 

UL 1581 

CSA C22.2 No. 239 Type CIC

Flame Tests Compliances: 

UL 1581 VW-1 

UL 1277 

CSA FT-4 

IEEE 383 

Other Compliances: 

EPA 40 CFR, Part 261 for leachable lead content per TCLP 

OSHA acceptable 

Product Parameter

AWG Size

Conductor Stranding

No. of Pairs

No. of Triads

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. (in)

Approx LBS/MFT

18

7/0.0152

1

0.03

0.045

0.315

46

18

7/0.0152

1

0.03

0.045

0.34

57

18

7/0.0152

2

0.03

0.045

0.45

88

18

7/0.0152

4

0.03

0.045

0.56

144

18

7/0.0152

8

0.03

0.06

0.75

263

18

7/0.0152

12

0.03

0.08

0.85

358

18

7/0.0152

16

0.03

0.08

1.01

461

18

7/0.0152

20

0.03

0.08

1.085

600

18

7/0.0152

24

0.03

0.08

1.21

761

18

7/0.0152

36

0.03

0.08

1.5

1005

18

7/0.0152

50

0.03

0.08

2.57

1603

16

7/0.0192

1

0.03

0.045

0.345

32

16

7/0.0192

1

0.03

0.045

0.36

71

16

7/0.0192

2

0.03

0.045

0.56

121

16

7/0.0192

4

0.03

0.06

0.65

186

16

7/0.0192

8

0.03

0.06

0.81

324

16

7/0.0192

12

0.03

0.08

1

486

16

7/0.0192

16

0.03

0.08

1.12

616

16

7/0.0192

20

0.03

0.08

1.17

734

16

7/0.0192

24

0.03

0.08

1.44

894

16

7/0.0192

36

0.03

0.08

1.65

1254

16

7/0.0192

50

0.03

0.11

2.02

1800

XLPE/Arctic-Grade PVC Instrumentation Cable with Individual and Overall Shielded Pairs 

Applications:

Typical applications include industrial lighting, control and signaling circuits. 

Primary installations cable trays, raceways or outdoor applications where supported by messenger wire 

In wet or dry locations 

Features:

Rated at 90°C wet or dry 

Ripcord applied to all cables with jacket thickness of 60 mils or less 

Sunlight and weather resistant 

Meets CSA cold impact test at -40°C 

Meets ICEA and CSA cold bend test at -65°C

Construction: 

Conductor: 

18 AWG and 16 AWC tinned, annealed copper per ASTM B33 

Class B stranding per ASTM B8

Insulation: 

Flame-retardant Cross-Linked Polyethylene (XLPE) 

Color-coded per ICEA Method 1: 

Pairs: Black and White 

Shield: 

Individual pairs are 100% shielded with aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: 

Flame-retardant and sunlight-resistant Arctic-grade Polyvinyl Chloride (PVC)

Options: 

Bare copper conductor 

Class C Stranding 

E-2 Color Code 

CSA Rated TC for 14 AWG and larger 

Other constructions available upon request 

Approvals: 

Industry Compliances: 

UL 1277 Type TC 

UL 1581 

CSA C22.2 No. 239 Type CIC

Flame Tests Compliances: 

UL 1581 VW-1 

UL 1277 

CSA FT-4 

IEEE 383 

Other Compliances: 

EPA 40 CFR, Part 261 for leachable lead content per TCLP 

OSHA acceptable 

Product Parameter

AWG Size

Conductor Stranding

No. of Pairs

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. of Cable (in)

Approx LBS/MFT

18

7/0.0152

2

0.03

0.06

0.595

42

18

7/0.0152

4

0.03

0.06

0.695

80

18

7/0.0152

8

0.03

0.06

0.9

155

18

7/0.0152

12

0.03

0.08

1.11

230

18

7/0.0152

16

0.03

0.08

1.26

306

18

7/0.0152

20

0.03

0.08

1.315

375

18

7/0.0152

24

0.03

0.08

1.51

456

18

7/0.0152

36

0.03

0.11

1.82

674

18

7/0.0152

50

0.03

0.11

2.095

946

16

7/0.0192

2

0.03

0.06

0.595

132

16

7/0.0192

4

0.03

0.06

0.695

212

16

7/0.0192

8

0.03

0.06

0.9

395

16

7/0.0192

12

0.03

0.08

1.11

578

16

7/0.0192

16

0.03

0.08

1.26

733

16

7/0.0192

20

0.03

0.08

1.315

845

16

7/0.0192

24

0.03

0.08

1.51

1009

16

7/0.0192

36

0.03

0.11

1.82

1259

16

7/0.0192

50

0.03

0.11

2.095

2032

XLPE/PVC Instrumentation Cable with Overall Shielded Pairs/Triads 

Applications:

In free air, raceways or direct burial 

In wet or dry locations 

Permitted for use in Class I Division 2 Industrial hazardous locations per NEC 

Features:

Rated at 90°C wet or dry 

Ripcord applied to all cables with jacket thickness of 60 mils or less 

Abrasion- and chemical-resistant 

Sunlight and weather resistant 

Excellent electrical properties 

Meets cold bend test at -25°C

Construction: 

Conductor: 

18 AWG and 16 AWC bare, annealed copper per ASTM B3 

Class B stranding per ASTM B8

Insulation: 

Flame-retardant Cross-Linked Polyethylene (XLPE) 

Color-coded per ICEA Method 1: 

Pairs: Black and White 

Triads: Black, White and Red

Shield: 

Overall shield is aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: 

Flame-retardant and sunlight-resistant Arctic-grade Polyvinyl Chloride (PVC)

Options: 

300V Type PLTC 

Tinned copper conductor 

Class C Stranding 

Individual and overall shielded pairs/triads 

EVTC-Ethylene Propylene Rubber (EPR) insulation 

Other constructions available upon request 

Approvals: 

Industry Compliances: 

UL 1277 Type TC 

UL 1581 

ICEA S-82-552 

ICEA S-73-532

Flame Tests Compliances: 

UL 1581 VW-1 

UL 1277 

IEEE 383 

IEEE 1202 

CSA FT-4 

Other Compliances: 

EPA 40 CFR, Part 261 for leachable lead content per TCLP 

OSHA acceptable

Product Parameter

AWG Size

Conductor Stranding

No. of Pairs

No. of Triads

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D. (in)

Approx LBS/MFT

18

7/0.0152

1

0.03

0.045

0.315

46

18

7/0.0152

1

0.03

0.045

0.34

58

18

7/0.0152

2

0.03

0.045

0.45

88

18

7/0.0152

4

0.03

0.045

0.56

144

18

7/0.0152

8

0.03

0.06

0.75

263

18

7/0.0152

12

0.03

0.08

0.85

358

18

7/0.0152

16

0.03

0.08

1.01

461

18

7/0.0152

20

0.03

0.08

1.085

600

18

7/0.0152

24

0.03

0.08

1.21

701

18

7/0.0152

36

0.03

0.08

1.5

1005

18

7/0.0152

50

0.03

0.08

2.57

1603

16

7/0.0192

1

0.03

0.045

0.345

32

16

7/0.0192

1

0.03

0.045

0.36

72

16

7/0.0192

2

0.03

0.045

0.56

121

16

7/0.0192

4

0.03

0.06

0.65

186

16

7/0.0192

8

0.03

0.06

0.81

324

16

7/0.0192

12

0.03

0.08

1

486

16

7/0.0192

16

0.03

0.08

1.12

616

16

7/0.0192

20

0.03

0.08

1.17

734

16

7/0.0192

24

0.03

0.08

1.44

894

16

7/0.0192

36

0.03

0.08

1.65

1254

16

7/0.0192

50

0.03

0.11

2.02

1800

XLPE/PVC Instrumentation Cable with Individual and Overall Shielded Pairs 

Applications:

In free air, raceways or direct burial 

In wet or dry locations 

Permitted for use in Class I Division 2 Industrial hazardous locations per NEC 

Features:

Rated at 90°C wet or dry 

Ripcord applied to all cables with jacket thickness of 60 mils or less 

Abrasion- and chemical-resistant 

Sunlight and weather resistant 

Excellent electrical properties 

Meets cold bend test at -25°C

Construction: 

Conductor: 

18 AWG and 16 AWC bare, annealed copper per ASTM B3 

Class B stranding per ASTM B8

Insulation: 

Flame-retardant Cross-Linked Polyethylene (XLPE) 

Color-coded per ICEA Method 1: 

Pairs: Black and White 

Shield: 

Individual and Overall shields are aluminum/polyester in contact with stranded tinned copper drain wire

Jacket: 

Flame-retardant and sunlight-resistant Arctic-grade Polyvinyl Chloride (PVC)

Options: 

300V Type PLTC 

Tinned copper conductor 

Class C Stranding 

Overall shielded pairs/triads 

EVTC-Ethylene Propylene Rubber (EPR) insulation 

Other constructions available upon request

Approvals: 

Industry Compliances: 

UL 1277 Type TC 

UL 1581 

ICEA S-82-552 

ICEA S-73-532

Flame Tests Compliances: 

UL 1581 VW-1 

UL 1277 

IEEE 383 

IEEE 1202 

CSA FT-4 

Other Compliances: 

EPA 40 CFR, Part 261 for leachable lead content per TCLP 

OSHA acceptable

Product Parameter

AWG Size

Conductor Stranding

No. of Pairs

Nom. Insul. Thick. (in)

Jacket Thick

Nom. O.D.  (in)

Approx LBS/MFT

18

7/0.0152

2

0.03

0.045

0.515

95

18

7/0.0152

4

0.03

0.06

0.625

170

18

7/0.0152

8

0.03

0.06

0.805

292

18

7/0.0152

12

0.03

0.08

1.02

442

18

7/0.0152

16

0.03

0.08

1.13

554

18

7/0.0152

20

0.03

0.08

1.235

666

18

7/0.0152

24

0.03

0.08

1.465

802

18

7/0.0152

36

0.03

0.08

1.63

1116

18

7/0.0152

50

0.03

0.11

1.975

1598

16

7/0.0192

2

0.03

0.06

0.595

135

16

7/0.0192

4

0.03

0.06

0.695

214

16

7/0.0192

8

0.03

0.06

0.9

399

16

7/0.0192

12

0.03

0.08

1.11

584

16

7/0.0192

16

0.03

0.08

1.26

712

16

7/0.0192

20

0.03

0.08

1.315

845

16

7/0.0192

24

0.03

0.08

1.51

1009

16

7/0.0192

36

0.03

0.11

1.82

1259

16

7/0.0192

50

0.03

0.11

2.095

2032

Nuclear SIS Wire (IEEE 383-1974) 

Applications:

SIS wire is 600V flexible single conductor, insulated, Class 1E rated 

For use in Class 1E low voltage applications in operation and interconnection of protective devices where optimum performance is required. 

Nuclear SIS Wire Features:

Rated at 90°C 

Fully traceable 

Qualified for 40-year service life 

Radiation resistant (up to 200 megarads) 

Long-term thermal endurance and superior electricals 

Excellent mechanical cut through properties 

Long-term moisture and radiation stability 

Free stripping for ease of termination 

Factory rework for service in nuclear power generating stations 

Construction: 

Conductor: 

18 AWG and 10 AWG tinned, annealed copper per ASTM B33; Class K stranding per ASTM B174 

8 AWG thru 1000 kcmil tinned, annealed copper per ASTM B33; Class H stranding per ASTM B173

Insulation: 

Nucular SIS Wire is flame-retardant, heat, moisture and radiation resistant, thermoset Cross-Linked Polyethylene (FR-XLPE) 

Color Code: Gray

Options: 

Conductor Stranding 

Bare Copper 

Full-colored insulation 

UL listed SIS/XHHW for sizes 14 AWG thru 4/0 AWG 

UL listed XHHW for kcmil sizes 

Approvals: 

Industry Compliances: 

Class 1E Qualified in accordance with IEEE 323-1974 and IEEE 383-1974 

ANSI N45.2 

ICEA S-95-658 (Formerly ICEA S-66-524 & S-19-81) 

Flame Tests Compliances: 

IEEE 383 (70,000 BTU/hr) 

ICEA T-29-520 (210,000 BTU/hr) 

UL VW-1 

Other Compliances: 

Quality assurance program in accordance with NRC 10CFR50 Appendix B 

ASME NQA-1:2000 

NUPIC

Product Parameter

AWG Size

Conductor Stranding

Nom. Insul. Thick. (in)

Nom. O.D. (in)

Approx LBS/MFT

18

16/0.010

0.03

0.108

9

16

26/0.010

0.03

0.119

13

14

41/0.010

0.03

0.133

18

12

65/0.010

0.03

0.15

27

10

105/0.010

0.03

0.174

41

8

133/0.0111

0.045

0.257

70

6

133/0.0140

0.045

0.299

105

4

133/0.0177

0.045

0.353

160

2

133/0.0223

0.045

0.42

244

1

259/0.0180

0.055

0.476

312

1/0

259/0.0202

0.055

0.52

386

2/0

259/0.0227

0.055

0.571

481

3/0

259/0.0255

0.055

0.628

600

4/0

259/0.0286

0.055

0.714

746

250

427/0.0242

0.065

0.761

888

350

427/0.0286

0.065

0.874

1221

500

427/0.0342

0.065

1.034

1728

750

703/0.0327

0.08

1.286

2611

1000

703/0.0377

0.08

1.458

3441

 

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com