Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 

 

  Marine, OIL,GAS & Petrochemical Cables 

British Standard Shipwiring cables to BS 6883

Unarmoured flexible screened instrumentation cables

Unarmoured flexible screened instrumentation cables

Manufactured in both pairs and triples these 150/250V instrumentation cables provide collective or individual screening through the use of metallic foils and drain wires. Offering good flexibility for installation in confined spaces or where difficult routing is necessary these cables are ideal where no additional mechanical protection is required.

 

Core Identification

Pairs : Each pair black, white and numbered
Triples :  

Each triple black, white, red and numbered

(Alternative colour codes are available)

Technical Information

Voltage rating 150/250V
Conductors Tinned, BS6360 class 2 or class 5
Temperature rating +90°C maximum conductor temperature
Static temperature rating -30°C to +90°C
Bending radius (static) 8 x cable O/D
Flame retardant IEC60332 part 3A, BS4066 part 3A

Technical Data

No. of
Pairs
Nominal Conductor
Cross-Sectional
Area mm²
Nominal Diameter
of Cable
Min-Max mm
 Pairs collective
 3   0.75   12.6 - 14.5 
 7   0.75   16.6 - 18.7 
 12   0.75   21.7 - 24.2 
 20   0.75   27.3 - 30.1 
 27   0.75   31.1 - 34.2 
 37   0.75   34.4 - 37.7 
 3   1   13.3 - 15.3 
 7   1   17.6 - 19.8 
 12   1   23.1 - 25.7 
 20   1   29.1 - 31.9 
 27   1   33.3 - 36.6 
 37   1   36.9 - 40.3 
 Pairs individual
 1   0.75   7.3 - 9.0 
 3   0.75   12.6 - 14.5 
 7   0.75   16.9 - 19.0 
 12   0.75   21.2 - 23.7 
 20   0.75   27.0 - 29.8 
 27   0.75   30.8 - 33.9 
 37   0.75   35.9 - 39.3 
 1   1   7.7 - 9.5 
 3   1   13.5 - 15.5 
 7   1   18.0 - 20.1 
 12   1   22.8 - 25.4 
 20   1   28.8 - 31.6 
 27   1   32.8 - 36.0 
 37   1   38.5 - 42.3 
No. of
Triples
Nominal Conductor
Cross-Sectional
Area mm²
Diameter over
outer sheath
min-max mm
 Triples collective
 3   0.75   14.2 - 16.2 
 7   0.75   19.4 - 21.9 
 12   0.75   24.2 - 26.8 
 3   1   15.1 - 17.1 
 7   1   20.9 - 23.4 
 12   1   25.8 - 28.5 
 Triples individual
 1   0.75   7.7 - 9.4 
 3   0.75   14.2 - 16.2 
 7   0.75   19.7 - 22.1 
 12   0.75   24.4 - 27.1 
 1   1   8.4 - 10.1 
 3   1   15.0 - 17.2 
 7   1   21.0 - 23.5 
 12   1   26.2 - 28.9