Type SHD-GC Three-Conductor Portable Power Cable, TPU Sheath15kV
Applications
These heavy duty cables are designed for heavy mobile equipment such as drag lines, shovels, dredges, drills and for power feeders.
Standards
- ICEA S-75-381/NEMA WC 58
- ASTM B 172
- ASTM B 33
- CAN/CSA C22.2 No. 96
Construction
- Conductors: Stranded annealed tinned copper conductor.
- Insulation:EPR.
- Insulation Shield:Tinned copper/textile braid.
- Ground Check Conductor:Tinned copper conductor with a yellow polypropylene insulation.
- Grounding Conductor:Tinned copper conductor.
- Sheath: Thermoplastic Polyurethane (TPU) Jacket, black. Other sheath materials can be offered as an option.
Options
Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties
- Minimum Bending Radius: 6×OD
- Maximum Operating Temperature: +90℃
Dimensions and Weight
Construction |
No. of Strands |
Grounding Conductor Size |
Ground Check Conductor Size |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Nominal Sheath Thickness |
Nominal Weight |
Ampacity |
||||
No. of cores×AWG/kcmil |
- |
AWG/kcmil |
AWG/kcmil |
inch |
mm |
inch |
mm |
inch |
mm |
lbs/kft |
kg/km |
A |
3×2 |
259 |
6 |
8 |
0.210 |
5.3 |
0.235 |
6.0 |
2.41 |
61.2 |
3145 |
4679 |
164 |
3×1 |
259 |
5 |
8 |
0.210 |
5.3 |
0.235 |
6.0 |
2.52 |
64.0 |
3567 |
5307 |
187 |
3×1/0 |
266 |
4 |
8 |
0.210 |
5.3 |
0.250 |
6.4 |
2.64 |
67.0 |
3976 |
5916 |
215 |
3×2/0 |
323 |
3 |
8 |
0.210 |
5.3 |
0.250 |
6.4 |
2.73 |
69.3 |
4526 |
6734 |
246 |
3×3/0 |
418 |
2 |
8 |
0.210 |
5.3 |
0.265 |
6.7 |
2.90 |
73.7 |
5231 |
7783 |
283 |
3×4/0 |
532 |
1 |
8 |
0.210 |
5.3 |
0.265 |
6.7 |
3.05 |
77.5 |
6033 |
8976 |
325 |