Type SHD-PCG Three-Conductor Portable Power Cable 2kV

Applications

These heavy duty cables are designed for use on longwall shearers, where three shielded power conductors, three unshielded control conductors, and a grounding conductor are required.

Standards

  • ICEA S-75-381/NEMA WC 58
  • ASTM B 172
  • ASTM B 33
  • CAN/CSA-C22.2 No.96

Construction

  • Conductors: Stranded annealed tinned copper conductor.
  • Insulation:EPR.
  • Insulation Shield:Non-conducting Tape + Tinned copper/textile braid.
  • Control Group (3 Conductor):Tinned copper conductor, EPR insulation and thermosetting sheath. Colour of insulation: Black, white and red.
  • Grounding Conductor:Tinned copper conductor, located in the center of the cable.
  • Sheath: Reinforced extra-heavy-duty Chlorinated Polyethylene(CPE), black. Other sheath materials can be offered upon request.

Options

Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.

Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

  • Minimum Bending Radius: 6×OD
  • Maximum Operating Temperature: +90℃

Dimensions and Weight

Construction

No. of Strands

Grounding Conductor Size

Control Conductor Size

Nominal Insulation Thickness

Nominal Sheath Thickness

Nominal Overall Diameter

Nominal Weight

Ampacity

No. of cores×AWG/kcmil

-

AWG/kcmil

AWG/kcmil

inch

mm

inch

mm

inch

mm

lbs/kft

kg/km

A

3×1/0

259

3

8

0.08

2.0

0.205

5.2

2.05

52.1

3092

4602

211

3×2/0

329

2

8

0.08

2.0

0.220

5.6

2.25

57.1

3698

5503

243

3×3/0

413

1

8

0.08

2.0

0.220

5.6

2.32

58.9

4295

6392

279

3×4/0

532

1/0

8

0.08

2.0

0.250

6.3

2.62

66.5

5115

7612

321

Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.