Type SHD Three-Conductor Flat Portable Power Cable 2kV
Applications
These flat parallel cables are designed for use on continuous miners requiringgrounding conductors and metallic shieldingover each conductor.
Standards
- ICEA S-75-381/NEMA WC 58
- ASTM B 172
- ASTM B 33
Construction
- Conductors: Stranded annealed tinned copper conductor.
- Insulation:EPR.
- Insulation Shield:Tinned copper/textile braid.
- Grounding Conductor:Tinned copper conductor with semi-conductive thermoset compound.
- Sheath: Reinforced extra-heavy-duty Chlorinated Polyethylene(CPE), black. Other sheath materials can be offered as an option.
Options
Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.
Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.
Mechanical and Thermal Properties
- Minimum Bending Radius: 6×OD
- Maximum Operating Temperature: +90℃
Dimensions and Weight
Construction |
No. of Strands |
Grounding Conductor Size |
Nominal Insulation Thickness |
Nominal Overall Diameter Height×Width |
Nominal Weight |
Ampacity |
|||
No. of cores×AWG/kcmil |
- |
AWG/kcmil |
inch |
mm |
inch |
mm |
lbs/kft |
kg/km |
A |
3×2 |
259 |
6 |
0.07 |
1.8 |
0.94×2.45 |
23.9×62.2 |
2243 |
3338 |
159 |
3×1 |
259 |
5 |
0.08 |
2.0 |
1.04×2.64 |
26.4×67.1 |
2540 |
3780 |
184 |
3×1/0 |
259 |
4 |
0.08 |
2.0 |
1.08×2.82 |
27.4×71.6 |
2915 |
4338 |
211 |
3×2/0 |
329 |
3 |
0.08 |
2.0 |
1.18×2.99 |
30.0×76.0 |
3346 |
4980 |
243 |
3×3/0 |
413 |
2 |
0.08 |
2.0 |
1.25×3.29 |
31.8×83.6 |
3890 |
5789 |
279 |
Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.