Application
Multicore power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360
Insulation
Electronbeam crosslinkable thin wall LSZH compound
Outer Sheath
Electron beam crosslinkable LSZH compound
Optional
FRA-TW-0.75M-OS (Screened)
FRA-TW-0.75M-FR (Fire resistant)
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section |
AWG |
20 |
18 |
16 |
14 |
12 |
10 |
| Maximum Conductor Resistance |
Ω/km |
28.3 |
17.9 |
14.1 |
8.3 |
6.8 |
3.6 |
| Voltage Rating |
KV |
0.45/0.75 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code |
No. of cores& Nominal
Conductor Cross
Sectional Area
No. x AWG |
Nominal Diameter
of Strands
No/mm |
Nominal Insulation
Thickness
mm |
Nominal Overall
Diameter
mm |
|
FRA-TW-0.75M-2C20A |
2×20 |
19/0.2 |
0.18 |
4.2 |
32 |
FRA-TW-0.75M-2C18A |
2×18 |
19/0.25 |
0.18 |
4.6 |
39 |
FRA-TW-0.75M-2C16A |
2×16 |
19/0.3 |
0.18 |
5.3 |
54 |
FRA-TW-0.75M-2C14A |
2×14 |
37/0.25 |
0.22 |
6.1 |
66 |
FRA-TW-0.75M-2C12A |
2×12 |
37/0.3 |
0.28 |
7.3 |
92 |
FRA-TW-0.75M-3C20A |
3×20 |
19/0.2 |
0.18 |
4.4 |
46 |
FRA-TW-0.75M-3C18A |
3×18 |
19/0.25 |
0.18 |
4.95 |
62 |
FRA-TW-0.75M-4C20A |
4×20 |
19/0.2 |
0.18 |
4.65 |
59 |
FRA-TW-0.75M-4C18A |
4×18 |
19/0.25 |
0.18 |
5.2 |
80 |
FRA-TW-0.75M-4C16A |
4×16 |
19/0.3 |
0.18 |
6.0 |
104 |