Application
Single Core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
● BS 6387
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Flame Barrier
Mica tape.
Insulation
Electron beam crosslinkable medium wall LSZH compound.
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section |
mm² |
1.0 |
1.5 |
2.5 |
4.0 |
6.0 |
10 |
16 |
| Maximum Conductor Resistance |
Ω/km |
20.0 |
13.7 |
8.21 |
5.09 |
3.39 |
1.95 |
1.24 |
| Voltage Rating |
KV |
0.6/1.0 |
| Nominal Conductor Cross Section |
mm² |
25 |
35 |
50 |
70 |
95 |
150 |
| Maximum Conductor Resistance |
Ω/km |
0.795 |
0.565 |
0.393 |
0.277 |
0.21 |
0.132 |
| Voltage Rating |
KV |
0.6/1.0 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code |
No. of cores& Nominal
Conductor Cross
Sectional Area
No. x AWG |
Nominal Diameter
of Strands
No/mm |
Nominal Insulation
Thickness
mm |
Nominal Overall
Diameter
mm |
|
FRA-MW-1SU-FR-1G1 |
1×1.0 |
32/0.2 |
0.55 |
3.15 |
18.8 |
FRA-MW-1SU-FR-1G1.5 |
1×1.5 |
30/0.25 |
0.55 |
3.40 |
24 |
FRA-MW-1SU-FR-1G2.5 |
1×2.5 |
50/0.25 |
0.60 |
4.05 |
36.6 |
FRA-MW-1SU-FR-1G4 |
1×4 |
56/0.3 |
0.65 |
4.60 |
52.5 |
FRA-MW-1SU-FR-1G6 |
1×6 |
84/0.3 |
0.70 |
5.30 |
73 |
FRA-MW-1SU-FR-1G10 |
1×10 |
80/0.4 |
0.80 |
6.35 |
121 |
FRA-MW-1SU-FR-1G16 |
1×16 |
126/0.4 |
0.90 |
8.15 |
181 |
FRA-MW-1SU-FR-1G25 |
1×25 |
196/0.4 |
1.00 |
9.65 |
261 |
FRA-MW-1SU-FR-1G35 |
1×35 |
276/0.4 |
1.10 |
10.80 |
365 |
FRA-MW-1SU-FR-1G50 |
1×50 |
396/0.41 |
1.20 |
12.80 |
530 |
FRA-MW-1SU-FR-1G70 |
1×70 |
360/0.50 |
1.30 |
15.10 |
730 |
FRA-MW-1SU-FR-1G95 |
1×95 |
475/0.50 |
1.40 |
17.00 |
930 |
FRA-MW-1SU-FR-1G150 |
1×150 |
756/0.50 |
1.60 |
21.30 |
1450 |