Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Railway Cables

NSGAFOU Cables

Application

The cables are designed for use in switch cabinets, wiring of devices, trains and buses as well as in dry rooms.

Standards

● DIN VDE 0250-602

Construction

Conductors
Flexible tinned copper to IEC 60228 class 5.

Insulation
EPR type 3G13.

Outer sheath
PCP type 5GM3.

Electrical Characteristics at 20℃

Nominal Conductor Cross Section
mm²
1.5
2.5
4.0
6.0
10
16
25
35
Conductor Resistance
Ω/km
13.7
8.21
5.09
3.39
1.95
1.24
0.795
0.565
Current Rating
A
31
41
58
75
103
145
194
240
Voltage Rating
KV
1.8/3

 

Nominal Conductor Cross Section
mm²
50
70
95
120
150
185
240
Conductor Resistance
Ω/km
0.393
0.277
0.21
0.164
0.132
0.109
0.0817
Current Rating
A
301
372
456
528
607
639
821
Voltage Rating
KV
1.8/3

Mechanical and Thermal Properties

Minimum Bending Radius: 4×OD
Temperature Range:-25℃ to +80℃ (during operation); -10℃ to +60℃ (during installation)

Dimensions And Weight

Cable Code
No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm²
No. & Nominal
Diameter of
Strands
No/mm
Nominal
Insulation
Thickness
mm
Nominal
Overall
Diameter
mm
Nominal
Weight
kg/km

RF602-NSGAFOU-1G1.5

1×1.5

30/0.25

1.3

6.5

59

RF602-NSGAFOU-1G2.5

1×2.5

50/0.25

1.3

6.8

74

RF602-NSGAFOU-1G4

1×4.0

56/0.3

1.3

7.7

94

RF602-NSGAFOU-1G6

1×6.0

84/0.3

1.3

8.3

118

RF602-NSGAFOU-1G10

1×10.0

80/0.4

1.5

9.2

163

RF602-NSGAFOU-1G16

1×16.0

126/0.4

1.5

10.1

220

RF602-NSGAFOU-1G25

1×25.0

196/0.40

1.8

12.5

336

RF602-NSGAFOU-1G35

1×35.0

276/0.40

1.8

14.0

470

RF602-NSGAFOU-1G50

1×50.0

396/0.40

1.8

15.5

581

RF602-NSGAFOU-1G70

1×70.0

360/0.50

1.8

17.0

772

RF602-NSGAFOU-1G95

1×95.0

475/0.50

2.2

19.5

1030

RF602-NSGAFOU-1G120

1×120.0

608/0.50

2.2

21.2

1280

RF602-NSGAFOU-1G150

1×150.0

756/0.50

2.2

23.5

1650

RF602-NSGAFOU-1G185

1×185.0

925/0.50

2.4

25.6

2050

RF602-NSGAFOU-1G240

1×240.0

1221/0.50

2.6

27.3

2590