Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Railway Cables

K26 LSZH 50/75Ω Coaxial Cables

Application

The 50Ω cables are HF transmission coaxial cables for GSM antennas, and the 75Ω cables are HF transmission coaxial cables for cameras (type KX6), and video surveillance (type 11 RTC). The Halogen-free cables are suitable for laid on hooks, and pulled through walls or through technical ducts.

Standards

● RATP K26
● Fire Performance: NF C 32070.2.2

Construction

Inner Conductors
50Ω cables:

Flexible Type (F)- solid copper coated aluminium (for 1/4″ , 3/8″ &1/2″ F conductor); red copper tube (for
7/8″ and 1'1/4 F conductor); corrugated red copper tube (for 1'5/8 F conductor).
Super Flexible Type (SF) - solid copper coated aluminium (for 3/8″ & 1/2″ SFconductor); helical corrugated
copper tube (for 7/8” SF conductor); copper wire (for 1/4″ SFconductor).
Extra Flexible (XF) – copper wire (for 1/4" XF conductor); solid copper coated aluminium (for 3/8" XF
conductor).

75Ω cables: solid red copper (for type 11 RTC) or red copper tube (for type KX6).

Dielectric
Cellular PE or natural PE (only for KX6 type).

Outer Conductor

50Ω cables: corrugated copper tube.
75Ω cables: copper braid.

Outer sheath
LSZH.

Electrical Characteristics at 20℃

50Ω Cables

Type of Cable
inch
1/4"F
3/8"F
1/2"F
7/8"F
1'1/4F
1'5/8F
Impedance
Ω
50
50
50
50
50
50
Attenuation
@10MHz
dB/100m
1.25
1.46
0.65
0.34
0.25
0.2
@150MHz
dB/100m
4.99
4.22
2.61
1.45
1.02
0.85
@200MHz
dB/100m
5.8
4.90
3.04
1.69
1.19
1.00
@450MHz
dB/100m
8.8
7.51
4.66
2.61
1.86
1.57
@900MHz
dB/100m
12.8
11.1
6.78
3.81
2.75
2.34
@1000MHz
dB/100m
13.5
11.6
7.18
4.04
2.93
2.49

@1500MHz

dB/100m

17.0

14.4

8.99

5.08

3.72

3.17

@1500MHz
dB/100m

18.3

15.5

9.64

5.45

4.01

3.42

Average Power Rating  

 

 

 

 

 

 

@10MHz
KW

5.79

7.23

13

28.0

41

57

@150MHz
KW

1.45

1.81

3.2

7.0

11

13

@200MHz
KW

1.25

1.56

2.75

6.0

9.0

11

@450MHz
KW

0.818

1.02

1.8

3.88

5.5

6.9

@900MHz
KW

0.566

0.70

1.25

2.65

3.83

4.49

@1000MHz
KW

0.533

0.663

1.18

2.50

3.60

4.20

@1500MHz
KW

0.426

0.53

0.947

1.99

2.82

3.22

@1700MHz
KW

0.398

0.494

0.884

1.85

2.61

2.96

Velocity of Propagation
%

85

88

88

88

88

88

 

Type of Cable

 

inch

1/4"SF

3/8"SF

1/2"SF

7/8"SF

1/4"XF

3/8"XF

Impedance
Ω
50 50 50 50 50 50
Attenuation

 

 

 

 

 

 

@10MHz
dB/100m

1.71

1.3

0.83

0.39

2.31

1.098

@150MHz
dB/100m

6.89

4.89

3.87

1.59

7.44

4.38

@200MHz
dB/100m

8.01

5.59

4.53

1.85

8.54

5.098

@450MHz
dB/100m

12.31

8.49

7.09

2.85

14.3

7.83

@900MHz
dB/100m

17.92

12.66

10.45

4.15

20.5

11.4

@1000MHz
dB/100m

18.98

13.5

11.09

4.4

21.83

12.1

@1500MHz
dB/100m

23.78

17.43

13.98

5.52

27.13

15.1

@1700MHz
dB/100m

25.51

18.91

15.03

5.92

29.5

16.2

Average Power Rating

 

 

 

 

 

 

@10MHz
KW

2.8

6.0

8.4

21.5

3.8

7.02

@150MHz
KW

0.7

1.52

2.1

5.4

0.9

1.76

@200MHz
KW

0.6

1.31

1.81

4.6

0.8

1.51

@450MHz
KW

0.39

0.86

1.18

3.0

0.51

0.99

@900MHz
KW

0.272

0.593

0.815

2.07

0.37

0.68

@1000MHz
KW

0.257

0.56

0.77

1.95

0.34

0.64

@1500MHz
KW

0.206

0.449

0.616

1.55

0.26

0.51

@1700MHz
KW

0.192

0.42

0.575

1.45

0.24

0.48

Velocity of Propagation
%

83

81

82

88

84

85

75Ω Cables

Type of Cable
inch
11 RTC
KX6
Impedance
Ω
75
75
@50MHz
dB/100m
2.5
8.13
@100MHz
dB/100m
3.6
11.73
@150MHz
dB/100m
4.6
14.73
@200MHz
dB/100m
5.4
16.92
@500MHz
dB/100m
8.5
27.0
@800MHz
dB/100m
10.5
35.1
@1000MHz
dB/100m
12.2
40.02
Velocity of Propagation
%
87
66

Mechanical and Thermal Properties

Minimum Bending Radius: 7.5×OD
Temperature Range:

50Ω cables: -40℃ to +85℃ (during operation); -20℃ to +60℃ (during installation);
75Ω cables: -20℃ to +85℃ (during operation); -10℃ to +60℃ (during installation).

Dimensions And Weight

50Ω Cables

Cable Code

 

Nominal Inner
Conductor Diameter
mm
Nominal Outer
Conductor Diameter
mm
Nominal Overall
Diameter
mm
Nominal Overall
Diameter
mm

1/4″ F Cable Type

RS/K26-F-HCAAYZ-50-6(1/4")

2.5

7.6

9.5

145

3/8″ F Cable Type

RS/K26-F-HCAAYZ-50-8(3/8")

3.3

9.5

11.5

204

1/2″ F Cable Type

RS/K26-F-HCAAYZ-50-12(1/2")

4.8

13.7

16.0

248

7/8″ F Cable Type

RS/K26-F-HCTAYZ-50-22(7/8")

9.0

24.8

27.75

575

1'1/4 F Cable Type

RS/K26-F-HCTAYZ-50-32(1'1/4)

13.0

35.7

39.5

1133

1'5/8 F Cable Type

RS/K26-F-HHTAYZ-50-42(1'5/8)

17.3

46.2

50.0

1631

1/4″ SF Cable Type

RS/K26-HRYZ-50-5(1/4" SF)

1.9

6.4

7.95

99

3/8″ SF Cable Type

RS/K26-HRCAYZ-50-7(3/8" SF)

2.8

9.6

11.15

159

1/2″ SF Cable Type

RS/K26-HRCAYZ-50-9(1/2" SF)

3.6

12.1

13.65

201

7/8″ SF Cable Type

RS/K26-HRCTYZ-50-22(7/8" SF)

9.4

25.0

27.5

550

1/4″ XF Cable Type

RS/K26-HRYZ-50-5(1/4" XF)

5.75

5.6

6.85

69

3/8″ XF Cable Type

RS/K26-HRCAYZ-50-7(3/8" XF)

2.76

8.0

10.1

111

*F = fl exible, SF = super fl exible, XF = extrafl exible

75Ω Cables

Cable Code
Nominal Inner
Conductor Diameter
mm
Nominal Outer Conductor
Diameter
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
11 RTC Cable Type
RS/K26-11RTC-BC80-H
1.7
7.85
10.3
115
KX6 Cable Type
RS/K26-KX6-BC80-H
0.6
4.85
7.2
66