Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Railway Cables

EAPSP n×1×1.4

Application

The cables are used as railway cables and can be installed directly into the ground or in ducts.

Standards

● RENFE E.T. 03.365.051.6

Construction

Conductors
Soft annealed solid copper, 1.4 mm nominal diameter.

Insulation
PE insulation.

Stranding
Cores are helically stranded in concentric layers.

Core Wrapping
Plastic tape(s) with overlapping.

Moisture Barrier
One laminated sheath made of aluminium tape (0.2mm thick) coated with copolymer on at least one side is applied longitudinally with overlap.

Inner Sheath
PE sheath.

Armour
One corrugated steel tape is longitudinally applied with overlap.

Outer Sheath
PE sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter
mm
1.4
Maximum Conductor Resistance
Ω/km
11.7
Minimum Insulation Resistance @500 V DC
MΩ.km
25000
Resistance Unbalance
%
2
Test Voltage @50Hz 1min
Core to Core
Veff
2100
Core to Screen
Veff
2500
Core to Armouring
Veff
2000

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD
Temperature Range: -30℃ to +70℃ (during operation); -10℃ +50℃ (during installation)

Dimensions And Weight

Cable Code

Number of
Cores
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
Inner
Outer

1.4mm Conductor, 2.6mm Insulated Wire

RS/EAPSP-2Y(L)2Y(SR)2Y-4C1.4

4

1.3

1.4

15.7

270

RS/EAPSP-2Y(L)2Y(SR)2Y-7C1.4

7

1.3

1.4

17.1

350

RS/EAPSP-2Y(L)2Y(SR)2Y-9C1.4

9

1.3

1.4

19.9

420

RS/EAPSP-2Y(L)2Y(SR)2Y-12C1.4

12

1.3

1.4

20.0

480

RS/EAPSP-2Y(L)2Y(SR)2Y-19C1.4

19

1.3

1.4

22.0

630

RS/EAPSP-2Y(L)2Y(SR)2Y-27C1.4

27

1.3

1.4

24.8

810

RS/EAPSP-2Y(L)2Y(SR)2Y-37C1.4

37

1.3

1.4

26.9

1010

RS/EAPSP-2Y(L)2Y(SR)2Y-48C1.4

48

1.3

1.4

29.7

1240

RS/EAPSP-2Y(L)2Y(SR)2Y-61C1.4

61

1.3

1.4

31.8

1490