Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Railway Cables

SXCAV & SXCAG Signalling Cables

Application

The cables are designed for connection between switching centers and equipment shelters along the trackside. The cables are used as main signalling cables specially designed to give good induction protection (R.F=0.24 at inductive voltage 170 V/km) and are suitable for installation in intercity railways electrifi ed at 25KV ac.

Standards

● SXCAV SXCAG Specifi cation
● Fire performance: EN 50266-2-4 C

Construction

Conductors
Class 1 solid bare copper conductor.

Insulation
Coloured cross-linked PE insulation.

Cabling Element
Each two conductors are twisted together to form a pair.

Stranding
Pairs are helically stranded in layers to form the cable core.

Core Wrapping
Plastic tape(s) with overlapping.

Inner Sheath
PE sheath.

Electrostatic Shield
One corrugated copper tape.

Intermediate Sheath
PE sheath.

Electromagnetic Shield
Two helically applied steel tapes.

Outer Sheath
Black unleaded PVC (SXCAV) or green halogen free (SXCAG) sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter
mm
1.38
Nominal Cross Section Area
mm²
1.5
Maximum Conductor Resistance (DC)
Ω/km
12.3
Minimum Insulation Resistance @500 V DC (3mins)
MΩ.km
10000
Maximum Mutual Capacitance @1000Hz (AC)
nF/km
60
Maximum Reduction Factor @170V/km 50Hz
0.24
Operating Voltage
V
1000

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD
Temperature Range: -25℃ to +90℃ (during operation); -10℃ to +90℃ (during installation)

Dimensions And Weight

SXCAV Cables

Cable Code
Number of
Pairs
Nominal Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
Inner
Inter.
Outer

1.38mm Conductor, 2.38mm Insulated Wire

RS/SXCAV-2Y2Y(K)2YBY-1P1.5S

1

1.0

0.8

1.6

16.9

513

RS/SXCAV-2Y2Y(K)2YBY-4P1.5S

4

1.0

0.8

1.6

23.1

826

RS/SXCAV-2Y2Y(K)2YBY-7P1.5S

7

1.0

0.8

1.7

26.1

1060

RS/SXCAV-2Y2Y(K)2YBY-14P1.5S

14

1.2

0.8

1.8

32.3

1571

RS/SXCAV-2Y2Y(K)2YBY-24P1.5S

24

1.2

1.1

2.0

38.3

2199

RS/SXCAV-2Y2Y(K)2YBY-30P1.5S

30

1.2

1.1

2.2

42.8

2555

SXCAG Cables

Cable Code
Number of
Pairs
Nominal Sheath Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
Inner
Inter.
Outer

1.38mm Conductor, 2.38mm Insulated Wire

RS/SXCAG-2Y2Y(K)2YBH-1P1.5S

1

1.0

0.8

1.6

16.9

515

RS/SXCAG-2Y2Y(K)2YBH-4P1.5S

4

1.0

0.8

1.6

23.1

855

RS/SXCAG-2Y2Y(K)2YBH-7P1.5S

7

1.0

0.8

1.7

26.1

1095

RS/SXCAG-2Y2Y(K)2YBH-14P1.5S

14

1.2

0.8

1.8

32.3

1616

RS/SXCAG-2Y2Y(K)2YBH-24P1.5S

24

1.2

1.1

2.0

38.3

2260

RS/SXCAG-2Y2Y(K)2YBH-30P1.5S

30

1.2

1.1

2.2

42.8

2625