Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Telephone Cables

 PVC Insulated Jumper Wires to IEC 60189-1

image of PVC Insulated Jumper Wires to IEC 60189-1

Application

The jumper wires are used for interconnection between terminal blocks at main distribution frames (MDF), cross connection cabinets (CCP) and distribution frames or boxes.

Standards

construction of PVC Insulated Jumper Wires to IEC 60189-1

• IEC 60189-1

• IEC 60332-1

• UL1581 Sec.VW-1

Construction

Conductors
Solid annealed tinned copper 0.5/0.6/0.8mm as per IEC 60228 Class 1

Insulation
PVC

Twisted Pairs
Insulated conductors are twisted into pairs with varying lays to minimize crosstalk

Electrical & Mechanical Properties

Nominal Conductor Diameter

mm

0.5

0.6

0.8

Conductor Size

mm2

0.196 0.283

0.5

Maximum Conductor Resistance @20°C

Ω/km

98 66

35

Minimum Insulation Resistance @500V DC

MΩ.km

50 50

50

Nominal Insulation Thickness

mm

0.225 0.225

0.275

Nominal Insulated Conductor Diameter

mm

0.95 1.05

1.35

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Color Code

Standard colour code is per IEC 60189-1

Dimensions And Weight

Cable Code

Number of Wires

Nominal Insulation
Thickness mm

Maximum Overall Diameter
mm

Nominal Weight kg/km

0.5mm Conductor, 0.95mm Insulated Wire
TC189-Y-1W05 1 0.225 1.25

2.5

TC189-Y-2W05 2 0.225 1.95

5.0

TC189-Y-3W05 3 0.225 2.25

7.5

TC189-Y-4W05 4 0.225 2.40

10.0

TC189-Y-5W05 5 0.225 2.60

12.5

0.6mm Conductor, 1.05mm Insulated Wire
TC189-Y-1W06 1 0.225 1.45

3.0

TC189-Y-2W06 2 0.225 2.15

6.0

TC189-Y-3W06 3 0.225 3.0

9.0

TC189-Y-4W06 4 0.225 3.4

12.0

0.8mm Conductor, 1.35mm Insulated Wire
TC189-Y-1W08 1 0.275 2.05

5.8

TC189-Y-2W08 2 0.275 2.75

11.6

TC189-Y-3W08 3 0.275 3.7

17.4

TC189-Y-4W08 4 0.275 4.2

23.2