Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL, GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Control Cables  

IEC 60502 Type Cable

0.6/1 kV CVV
IEC 60502 (2-30 core)

Conductor: Concentric Stranded copper wire
Insulation: PVC Black color
Identification : Printed White number on the surface of Black insulation
Filler: Suitable filler
Binding tape: Suitable tape
Sheath : PVC Black color
Application: For supervisory electrical equipment, station control circuits, outdoor, suitable installation in dry or wet cable trenches.

2 Core CVV Control Cable
3 Core CVV Control Cable
4 Core CVV Control Cable
5 Core CVV Control Cable
6 Core CVV Control Cable
7 Core CVV Control Cable
8 Core CVV Control Cable
9 Core CVV Control Cable
10 Core CVV Control Cable
11 Core CVV Control Cable
12 Core CVV Control Cable
13 Core CVV Control Cable
14 Core CVV Control Cable

15 Core CVV Control Cable
16 Core CVV Control Cable
17 Core CVV Control Cable
18 Core CVV Control Cable
19 Core CVV Control Cable
20 Core CVV Control Cable
21 Core CVV Control Cable
22 Core CVV Control Cable
23 Core CVV Control Cable
24 Core CVV Control Cable
25 Core CVV Control Cable
26 Core CVV Control Cable
27 Core CVV Control Cable
28 Core CVV Control Cable
29 Core CVV Control Cable
30 Core CVV Control Cable

2 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-2C0.50SQ

2

0.5

7/0.30

0.8

1.8

10.0

36.0

0.0162

98

500/D

CCL-CT-CVV-2C0.75SQ

0.75

7/0.37

0.8

1.8

10.0

24.5

0.0142

110

500/D

CCL-CT-CVV-2C1.00SQ

1

7/0.40

0.8

1.8

10.5

18.1

0.0135

115

500/D

CCL-CT-CVV-2C1.50SQ

1.5

7/0.50

0.8

1.8

11.0

12.1

0.0115

135

500/D

CCL-CT-CVV-2C2.50SQ

2.5

7/0.67

0.8

1.8

12.0

7.41

0.0093

180

500/D

CCL-CT-CVV-2C4.00SQ

4

7/0.85

1.0

1.8

14.5

4.61

0.0092

255

500/D

CCL-CT-CVV-2C6.00SQ

6

7/1.04

1.0

1.8

15.5

3.08

0.0078

320

500/D

3 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-3C0.50SQ

3

0.5

7/0.30

0.8

1.8

10.0

36.0

0.0162

110

500/D

CCL-CT-CVV-3C0.75SQ

0.75

7/0.37

0.8

1.8

10.5

24.5

0.0142

125

500/D

CCL-CT-CVV-3C1.00SQ

1

7/0.40

0.8

1.8

11.0

18.1

0.0135

135

500/D

CCL-CT-CVV-3C1.50SQ

1.5

7/0.50

0.8

1.8

11.5

12.1

0.0115

160

500/D

CCL-CT-CVV-3C2.50SQ

2.5

7/0.67

0.8

1.8

13.0

7.41

0.0093

220

500/D

CCL-CT-CVV-3C4.00SQ

4

7/0.85

1.0

1.8

15.0

4.61

0.0092

315

500/D

CCL-CT-CVV-3C6.00SQ

6

7/1.04

1.0

1.8

16.5

3.08

0.0078

405

500/D

4 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-4C0.50SQ

4

0.5

7/0.30

0.8

1.8

11.0

36.0

0.0162

130

500/D

CCL-CT-CVV-4C0.75SQ

0.75

7/0.37

0.8

1.8

11.5

24.5

0.0142

150

500/D

CCL-CT-CVV-4C1.00SQ

1

7/0.40

0.8

1.8

11.5

18.1

0.0135

160

500/D

CCL-CT-CVV-4C1.50SQ

1.5

7/0.50

0.8

1.8

12.5

12.1

0.0115

195

500/D

CCL-CT-CVV-4C2.50SQ

2.5

7/0.67

0.8

1.8

14.0

7.41

0.0093

265

500/D

CCL-CT-CVV-4C4.00SQ

4

7/0.85

1.0

1.8

16.5

4.61

0.0092

390

500/D

CCL-CT-CVV-4C6.00SQ

6

7/1.04

1.0

1.8

17.0

3.08

0.0078

510

500/D

5 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-5C0.50SQ

5

0.5

7/0.30

0.8

1.8

11.5

36.0

0.0162

150

500/D

CCL-CT-CVV-5C0.75SQ

0.75

7/0.37

0.8

1.8

12.5

24.5

0.0142

175

500/D

CCL-CT-CVV-5C1.00SQ

1

7/0.40

0.8

1.8

12.5

18.1

0.0135

190

500/D

CCL-CT-CVV-5C1.50SQ

1.5

7/0.50

0.8

1.8

13.5

12.1

0.0115

230

500/D

CCL-CT-CVV-5C2.50SQ

2.5

7/0.67

0.8

1.8

15.0

7.41

0.0093

320

500/D

CCL-CT-CVV-5C4.00SQ

4

7/0.85

1.0

1.8

18.0

4.61

0.0092

470

500/D

CCL-CT-CVV-5C6.00SQ

6

7/1.04

1.0

1.8

19.5

3.08

0.0078

620

500/D

6 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-6C0.50SQ

6

0.5

7/0.30

0.8

1.8

12.5

36.0

0.0162

165

500/D

CCL-CT-CVV-6C0.75SQ

0.75

7/0.37

0.8

1.8

13.0

24.5

0.0142

190

500/D

CCL-CT-CVV-6C1.00SQ

1

7/0.40

0.8

1.8

13.5

18.1

0.0135

205

500/D

CCL-CT-CVV-6C1.50SQ

1.5

7/0.50

0.8

1.8

14.5

12.1

0.0115

255

500/D

CCL-CT-CVV-6C2.50SQ

2.5

7/0.67

0.8

1.8

16.0

7.41

0.0093

355

500/D

CCL-CT-CVV-6C4.00SQ

4

7/0.85

1.0

1.8

19.5

4.61

0.0092

525

500/D

CCL-CT-CVV-6C6.00SQ

6

7/1.04

1.0

1.8

21.0

3.08

0.0078

690

500/D

7 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-7C0.50SQ

7

0.5

7/0.30

0.8

1.8

12.5

36.0

0.0162

170

500/D

CCL-CT-CVV-7C0.75SQ

0.75

7/0.37

0.8

1.8

13.0

24.5

0.0142

200

500/D

CCL-CT-CVV-7C1.00SQ

1

7/0.40

0.8

1.8

13.5

18.1

0.0135

215

500/D

CCL-CT-CVV-7C1.50SQ

1.5

7/0.50

0.8

1.8

14.5

12.1

0.0115

270

500/D

CCL-CT-CVV-7C2.50SQ

2.5

7/0.67

0.8

1.8

16.0

7.41

0.0093

380

500/D

CCL-CT-CVV-7C4.00SQ

4

7/0.85

1.0

1.8

19.5

4.61

0.0092

570

500/D

CCL-CT-CVV-7C6.00SQ

6

7/1.04

1.0

1.8

21.0

3.08

0.0078

795

500/D

8 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-8C0.50SQ

8

0.5

7/0.30

0.8

1.8

13.5

36.0

0.0162

195

500/D

CCL-CT-CVV-8C0.75SQ

0.75

7/0.37

0.8

1.8

14.0

24.5

0.0142

230

500/D

CCL-CT-CVV-8C1.00SQ

1

7/0.40

0.8

1.8

14.5

18.1

0.0135

250

500/D

CCL-CT-CVV-8C1.50SQ

1.5

7/0.50

0.8

1.8

15.5

12.1

0.0115

310

500/D

CCL-CT-CVV-8C2.50SQ

2.5

7/0.67

0.8

1.8

17.5

7.41

0.0093

440

500/D

CCL-CT-CVV-8C4.00SQ

4

7/0.85

1.0

1.8

21.0

4.61

0.0092

660

500/D

CCL-CT-CVV-8C6.00SQ

6

7/1.04

1.0

1.8

23.0

3.08

0.0078

875

500/D

9 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-9C0.50SQ

9

0.5

7/0.30

0.8

1.8

14.0

36.0

0.0162

220

500/D

CCL-CT-CVV-9C0.75SQ

0.75

7/0.37

0.8

1.8

15.0

24.5

0.0142

265

500/D

CCL-CT-CVV-9C1.00SQ

1

7/0.40

0.8

1.8

15.5

18.1

0.0135

285

500/D

CCL-CT-CVV-9C1.50SQ

1.5

7/0.50

0.8

1.8

16.5

12.1

0.0115

355

500/D

CCL-CT-CVV-9C2.50SQ

2.5

7/0.67

0.8

1.8

18.5

7.41

0.0093

505

500/D

CCL-CT-CVV-9C4.00SQ

4

7/0.85

1.0

1.8

22.5

4.61

0.0092

760

500/D

CCL-CT-CVV-9C6.00SQ

6

7/1.04

1.0

1.8

24.5

3.08

0.0078

1015

500/D

10 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-10C0.50SQ

10

0.5

7/0.30

0.8

1.8

15.5

36.0

0.0162

240

500/D

CCL-CT-CVV-10C0.75SQ

0.75

7/0.37

0.8

1.8

16.0

24.5

0.0142

285

500/D

CCL-CT-CVV-10C1.00SQ

1

7/0.40

0.8

1.8

16.5

18.1

0.0135

310

500/D

CCL-CT-CVV-10C1.50SQ

1.5

7/0.50

0.8

1.8

18.0

12.1

0.0115

385

500/D

CCL-CT-CVV-10C2.50SQ

2.5

7/0.67

0.8

1.8

20.0

7.41

0.0093

550

500/D

CCL-CT-CVV-10C4.00SQ

4

7/0.85

1.0

1.8

24.5

4.61

0.0092

825

500/D

CCL-CT-CVV-10C6.00SQ

6

7/1.04

1.0

1.8

27.0

3.08

0.0078

1100

500/D

11 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-11C0.50SQ

11

0.5

7/0.30

0.8

1.8

15.5

36.0

0.0162

255

500/D

CCL-CT-CVV-11C0.75SQ

0.75

7/0.37

0.8

1.8

16.5

24.5

0.0142

315

500/D

CCL-CT-CVV-11C1.00SQ

1

7/0.40

0.8

1.8

17.0

18.1

0.0135

340

500/D

CCL-CT-CVV-11C1.50SQ

1.5

7/0.50

0.8

1.8

18.5

12.1

0.0115

425

500/D

CCL-CT-CVV-11C2.50SQ

2.5

7/0.67

0.8

1.8

21.0

7.41

0.0093

605

500/D

CCL-CT-CVV-11C4.00SQ

4

7/0.85

1.0

1.8

25.0

4.61

0.0092

915

500/D

CCL-CT-CVV-11C6.00SQ

6

7/1.04

1.0

1.8

27.5

3.08

0.0078

1220

500/D

12 Core CVV Control Cable

Part NO.

No. of core

Nominal
cross-
sectional area
sq.mm

No.& dia.
of wires No./mm

Thickness
of insulation mm

Thickness
of sheath
mm

Overall diameter (Approx.)
mm

Maximum conductor resistance
(at20C)
Ohm/km

Minimum insulation resistance
(at70C)
Ohm/km

Cable
weight (Approx.) kg/km

Standard Length
m

CCL-CT-CVV-12C0.50SQ

12

0.5

7/0.30

0.8

1.8

15.5

36.0

0.0162

265

500/D

CCL-CT-CVV-12C0.75SQ

0.75

7/0.37

0.8

1.8

16.5

24.5

0.0142

320

500/D

CCL-CT-CVV-12C1.00SQ

1

7/0.40

0.8

1.8

17.0

18.1

0.0135

345

500/D

CCL-CT-CVV-12C1.50SQ

1.5

7/0.50

0.8

1.8

18.5

12.1

0.0115

440

500/D

CCL-CT-CVV-12C2.50SQ

2.5

7/0.67

0.8

1.8

21.0

7.41

0.0093

630

500/D

CCL-CT-CVV-12C4.00SQ

4