Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL, GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Control Cables  

VDE Standard Control Cable

SY PVC /PVC/GSWB/PVC Control Cable

Application: For use as a measuring, control and signal cable for the machine tool industry, plant construction, heating and air conditioning, and as a flexible cable between fixed and mobile equipment. The cable is well protected against mechanical damage by the narrow weave steel-wire braid.
• Note: should not be used in any installations where the cable is subjected to repetitive flexing.
Standards: Generally BS6500 VDE0250
Conductor: Class 5 annealed copper conductors to BS6360 / VDE0295
Insulation: PVC
Bedding: PVC
Braiding: Galvanized Steel Wire Braid (GSWB)
Sheath: PVC (Type TM2 to BS7655)
Voltage Rating: 300/500V
Tempe rature rating:Flexing -15 to +70°C,Static -35 to +70°C
Minimum bending radius: 6 x overall diameter
Core identification: Black with White numbers. (3 core and above to include Green/Yellow)
Coloured cores available on request
Current Carrying Capacity (amperes)

Nominal Cross Sectional Area

Single Phase AC or DC

Three Phase AC

mm2

Amps

Amps

0.5

3

3

0.8

6

6

1.0

10

10

1.5

16

16

2.5

25

20

4.0

32

25

6.0

51

43

10.0

70

60

16.0

94

80

16.0

94

80

The above ratings are based on cable in Free air, in an ambient air temperature of 30°C.

For ambient air temperatures other than 30°C the following rating factors should be applied:
Ratings for cables up to and including 4mm2 are based on 60°C conductor operating temperature with 6mm2 and above based on 70°C operating temperature.

Correction Factors
Cables Up To and Including 4mm2 . Assuming 60°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

Correction Factor

0.91

0.82

0.71

0.58

0.41


Cables 6mm2 and above . Assuming 70°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

60°C

Correction Factor

0.91

0.82

0.71

0.58

0.41

0.50

3 Core SY control cable

Part NO.

No. of Cores

Nominal Cross Sectional Area

Nominal No. and Size of Wires

Nominal Overall Diameter

Nominal Weight

 

mm2

#/mm

mm

kg/Km

CCL-CT-SY-3C1.00SQ

3

1.0

32/0.20

9.0

142

CCL-CT-SY-3C1.50SQ

3

1.5

30/0.25

10.2

186

CCL-CT-SY-3C2.50SQ

3

2.5

50/0.25

11.9

246

CCL-CT-SY-3C4.00SQ

3

4.0

56/0.30

15.1

330

CCL-CT-SY-3C6.00SQ

3

6.0

84/0.30

16.2

407

CCL-CT-SY-3C10.0SQ

3

10.0

80/0.40

20.1

621

CCL-CT-SY-3C16.0SQ

3

16.0

126/0.40

23.8

857

4 Core SY control cable

Part NO.

No. of Cores

Nominal Cross Sectional Area

Nominal No. and Size of Wires

Nominal Overall Diameter

Nominal Weight

 

mm2

#/mm

mm

kg/Km

CCL-CT-SY-4C1.00SQ

4

1.0

32/0.20

9.8

165

CCL-CT-SY-4C1.50SQ

4

1.5

30/0.25

10.9

212

CCL-CT-SY-4C2.50SQ

4

2.5

50/0.25

13.4

315

CCL-CT-SY-4C4.00SQ

4

4.0

56/0.30

16.4

457

CCL-CT-SY-4C6.00SQ

4

6.0

84/0.30

19.5

687

CCL-CT-SY-4C10.0SQ

4

10.0

80/0.40

24.2

1009

CCL-CT-SY-4C16.0SQ

4

16.0

126/0.40

27.1

1384


5 Core SY control cable

Part NO.

No. of Cores

Nominal Cross Sectional Area

Nominal No. and Size of Wires

Nominal Overall Diameter

Nominal Weight

mm2

#/mm

mm

kg/Km

CCL-CT-SY-5C1.00SQ

5

1.0

32/0.20

10.5

197

CCL-CT-SY-5C1.50SQ

5

1.5

30/0.25

11.7

241

CCL-CT-SY-5C2.50SQ

5

2.5

50/0.25

14.5

365

CCL-CT-SY-5C4.00SQ

5

4.0

56/0.30

17.7

545

CCL-CT-SY-5C6.00SQ

5

6.0

84/0.30

21.1

798

CCL-CT-SY-5C10.0SQ

5

10.0

80/0.40

26.2

1197

CCL-CT-SY-5C16.0SQ

5

16.0

126/0.40

30.6

1740

7 Core SY control cable

Part NO.

No. of Cores

Nominal Cross Sectional Area

Nominal No. and Size of Wires

Nominal Overall Diameter

Nominal Weight

mm2

#/mm

mm

kg/Km

CCL-CT-SY-7C1.00SQ

7

1.0

32/0.20

11.2

231

CCL-CT-SY-7C1.50SQ

7

1.5

30/0.25

13.1

310

CCL-CT-SY-7C2.50SQ

7

2.5

50/0.25

15.5

458

 

>>Return