Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Control Cables  

VDE Standard Control Cable

YY PVC/ PVC Number Coded

Application:Designed to offer a flexible solution for signalling, measuring and control applications.This range of cables are not only flexible but offer heat and oil protection.
Standards: Generally to BS6500 and VDE0250
Conductor: Flexible class 5 copper conductors to BS6360 / VDE0295
Insulation: PVC
Sheath: PVC
Voltage Rating: 300/500V
Temperature rating: Flexing -15 to +70°C
Static -35 to +70°C
Minimum bending radius: 6 x overall diameter
Core identification: Black with White numbers. (3 core and above to include Green/Yellow) Coloured cores available on request .

Current Carrying Capacity (amperes)

Nominal Cross Sectional Area

Single Phase AC or DC

Three Phase AC

mm2

Amps

Amps

0.75

6

6

1.0

10

10

1.5

16

16

2.5

25

20

4.0

32

25

6.0

51

43

10.0

70

60

16.0

94

80

For ambient air temperatures other than 30°C the following rating factors should be applied:
Ratings for cables up to and including 4mm2 are based on 60°C conductor operating temperature with 6mm2 and above based on 70°C operating temperature

Correction Factors
Cables Up To and Including 4mm2 , Assuming 60°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

Correction Factor

0.91

0.82

0.71

0.58

0.41

Cables 6mm2 and above, Assuming 70°C Conductor Temperature

Ambient Temperature

35°C

40°C

45°C

50°C

55°C

60°C

Correction Factor

0.91

0.82

0.71

0.58

0.41

0.50

3 core YY control cable

Part NO.

Number of Cores

 

Nominal Cross Sectional Area

mm2

No. and Nominal Diameter of Strands

#/mm

Nominal Overall Diameter

mm

Nominal Weight

kg/ km

CCL-CT-YY-3C0.75SQ

3

0.75

24/0.20

5.9

55

CCL-CT-YY-3C1.00SQ

3

1.0

32/0.20

6.4

67

CCL-CT-YY-3C1.50SQ

3

1.5

30/0.25

7.4

92

CCL-CT-YY-3C2.50SQ

3

2.5

50/0.25

9.5

153

CCL-CT-YY-3C4.00SQ

3

4.0

56/0.30

12.0

235

CCL-CT-YY-3C6.00SQ

3

6.0

84/0.30

12.8

305

CCL-CT-YY-3C10.0SQ

3

10.0

80/0.40

15.8

590

CCL-CT-YY-3C16.0SQ

3

16.0

126/0.40

18.4

800

4 core YY control cable

Part NO.

Number of Cores

Nominal Cross Sectional Area
mm2

No. and Nominal Diameter of Strands
#/mm

Nominal Overall Diameter
mm

Nominal Weight
kg/ km

CCL-CT-YY-4C0.75SQ

4

0.75

24/0.20

6.8

76

CCL-CT-YY-4C1.00SQ

4

1.0

32/0.20

7.4

89

CCL-CT-YY-4C1.50SQ

4

1.5

30/0.25

8.5

122

CCL-CT-YY-4C2.50SQ

4

2.5

50/0.25

10.4

191

CCL-CT-YY-4C4.00SQ

4

4.0

56/0.30

13.5

330

CCL-CT-YY-4C6.00SQ

4

6.0

84/0.30

16.0

480

CCL-CT-YY-4C10.0SQ

4

10.0

80/0.40

20.8

743

CCL-CT-YY-4C16.0SQ

4

16.0

126/0.40

24.1

1104

5 core YY control cable

Part NO.

Number of Cores

Nominal Cross Sectional Area
mm2

No. and Nominal Diameter of Strands
#/mm

Nominal Overall Diameter
mm

Nominal Weight
kg/ km

CCL-CT-YY-5C0.75SQ

5

0.75

24/0.20

7.4

88

CCL-CT-YY-5C1.00SQ

5

1.0

32/0.20

8.1

108

CCL-CT-YY-5C1.50SQ

5

1.5

30/0.25

9.3

148

CCL-CT-YY-5C2.50SQ

5

2.5

50/0.25

11.7

241

CCL-CT-YY-5C4.00SQ

5

4.0

56/0.30

14.7

404

CCL-CT-YY-5C6.00SQ

5

6.0

84/0.30

17.2

592

CCL-CT-YY-5C10.0SQ

5

10.0

80/0.40

22.9

920

CCL-CT-YY-5C16.0SQ

5

16.0

126/0.40

28.4

1370

7 core YY control cable

Part NO.

Number of Cores

Nominal Cross Sectional Area
mm2

No. and Nominal Diameter of Strands
#/mm

Nominal Overall Diameter
mm

Nominal Weight
kg/ km

CCL-CT-YY-7C0.75SQ

7

0.75

24/0.20

8.0

113

CCL-CT-YY-7C1.00SQ

7

1.0

32/0.20

8.8

140

CCL-CT-YY-7C1.50SQ

7

1.5

30/0.25

10.1

193

CCL-CT-YY-7C2.50SQ

7

2.5

50/0.25

12.9

311

 

>>Return