Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL,GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
    Fiber Optic Cables  
 

Ordering Options

        Multi Loose Tube Cable

                    CCL-FC-MLA-B-C×D-E-F-G-H×I-J-K-L
A: Loose tube diameter  
  B=2.1mm, C=2.5mm, D=2.8mm, E=3.0mm, F=3.2mm
B: Fiber type  
  0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber (OM3) per ITU-T G.651
5=50/125 multi-mode fi ber (OM2) per ITU-T G.651
6=62.5/125 multi-mode fi ber (OM1) per ITU-T G.651
7=NZDS SM fi ber per ITU-T G.656.
8=NZDS SM fi ber per ITU-T G.655.
9=Standard SM fi ber per ITU-T G.652.D
Ended with R=Ribbon type fi ber ( Ex: 9R= SM fi ber per G.652.D ribbon type )
C: No. of tubes:  
  1 to 36
D: No. of fi bers per tubes:  
  2 to 12
E: Central member  
  S=Solid steel, SR=Stranded steel, F=Fiber Reinforced Plastic (FRP)
F: Inner jacket options  
  2Y=PE, Y=PVC, H=LSZH
G: Armour options  
  Blank=No armour, T=Corrugated steel tape armour, W=Steel wire armour B=Bronze armour, D=Fiber glass armour; TW= Steel tape + Steel wire armour
H: Jacket material options  
  2Y=PE, Y=PVC, H=LSZH, 11Y=PU, A=Aluminium moisture barrier, T=Anti-termite protection
I: Water-blocking options for cable core  
  X=No water-blocking; J= Water blocking gel in tubes; JD=Water-blocking gel in tubes + dry water blocking in cable core interstices; JJ= Water-blocking gel in tubes and cable core interstices.
J: Water-blocking options for cables with more than one jacket
  X=No water-blocking, J= Water blocking gel between jackets; D=Dry water-blocking between cable jackets;
K: Strength member options  
  A=Aramid yarn, AG=Aramid yarn and fi berglass yarn, G=Fiberlass yarn
L: General options  
  SS=Fig-8 self-supporting UW=Under Water

    ADSS Multi Loose Tube Cable

                 CCL-FC-MLA-B-C-D-E-F-G-H-I-J-K-L-M- ADSS
A: Loose tube diameter  
  B=2.1mm, C=2.5mm, D=2.8mm, E=3.0mm, F=3.2mm
B: Fiber type  
  0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber(OM3)
5=50/125 multi-mode fi ber(OM2)
6=50/125 multi-mode fi ber(OM1)
7=NZDS SM fi ber per G.656.
8=NZDS SM fi ber per G.655.
9=Standard SM fi ber per G.652.D
Ended with R=Ribbon type fi ber ( Ex: 9R= SM fi ber per G.652.D ribbon type )
C: No. of tubes:  
  01 to 36
D: No. of fi bers per tubes:  
  02 to 12
E: Central member  
  S=Solid steel, SR=Stranded steel, F=Dielectric(FRP)
F: Inner jacket options  
  2Y=PE, Y=PVC, H=LSZH
G: Armour options
  T=Corrugated steel tape armour, B=Bronze, W=Steel wire Armour, WB= Steel Wire
Braid
H: Jacket material options
  2Y=PE, AT= Anti-tracking
I: Water-blocking options for cable core  
  X=No water-blocking; J= Water blocking gel in tubes; JD=Water-blocking gel in tubes + dry water blocking in cable core interstices; JJ= Water-blocking gel in tubes and cable core interstices.
J: Water-blocking options for cables with more than one jacket
  X=No water-blocking, J= Water blocking gel between jackets;
K: Strength member options  
  A=Aramid yarn, AG=Aramid yarn and glass yarn, G=Glass yarn
L: Span Length  
M: Voltage Rating  

    Opgw Type Cable

CCL-FC-A-B-C-D-E-OPGW
A: Fiber type  
  0=Fiber and copper conductors in cable
4=50/125 multi-mode fi ber(OM3)
5=50/125 multi-mode fi ber(OM2)
6=50/125 multi-mode fi ber(OM1)
7=NZDS SM fi ber per G.656.
8=NZDS SM fi ber per G.655.
9=Standard SM fi ber per G.652.D
B: No. of steel tubes:  
  01 to 3
C: No. of fi bers per tubes:  
  02 to 12
D: Cross Sectional Area  
  35=35mm2; 50=50mm2; 70=70mm2; 90=90 mm2; 130=130mm2
E: Rated Voltage  
  66=66KV; 115=115kV; 150=150kV;
250=250kV; 275=275kV; 380=380kV; 500=500kV

                                        <<Return