Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 
Airport Cables

Alarm & Audio & Electronic Cables

Automotive Cables

Belden Equivalent Cables

Bus Cables
Coaxial Cables
Cable Glands

Cables for Oil Industry

Control Cables

Data Cable

Fiber Optic Cables

Fire Resisting Cables

Flexible Cables

Heat Detection Cables
High Temperature Cables
Highway Cables
Industrial Cables

Instrumentation Cables

Lan Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Medium Voltage Cables
Military Cables
Mining Cables
Motor Connecting Cables
Photovoltaic Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables
Undersea Cables
Windmill Cables
BS 5308
BS 5467
BS 6346
BS 6724
BS 7211
IEC 60502-1
Other Cables >>
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Special Cables

CALETRUCK M,N

Temperature range:

  • CALETRUCK M: -40°C to +85°C
  • CALETRUCK N: -40°C to +85°C

Test voltage:

  • CALETRUCK M: 2000 V
  • CALETRUCK N: 3000 V

Minimum bending radius:

  • CALETRUCK M: fixed installation 5x cable Ø
  • CALETRUCK N: fixed installation 15x cable Ø

Insulation resistance:

  • CALETRUCK M: min. 20 MOhm x km
  • CALETRUCK N: min. 20 MOhm x km

Nominal voltage:

  • CALETRUCK N: 75 V DC

Properties

  • CALETRUCK M:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Polarity easy to determine by a white line on the jacket above the white conductor
  • CALETRUCK N:
  • UV-resistant, largely resistant to oil, weather, and chemicals, self-extinguishing and flame retardant, test method B according to VDE 0472 part 804 and IEC 60332-1
  • Chemical resistance see table Technical Information
  • Complies with GGVS regulations
  • Approved and tested by the TÜV technical inspectorate
  • The additional jacket means that the cable is very robust, and can be installed without a corrugated conduit
  • Installation time is shorter due to twin design
  • Polarity is easy to determine even without stripping thanks to an imprint with the type designation and on the jacket over the positive conductor. This helps prevent wrong connections
  • The special construction of the conductor enables optimal crimping
  • Easy mechanical separation of the jacket web

CALETRUCK M

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x1.5 6.8 28.8 90.0 16
2x1.5 6.8 28.8 90.0 16
272 2x1.5 6.8 28.8 90.0 16

CALETRUCK N

Conductors x cross-sec. mm² Outer
Diameter
Copper weight
kg/km
Weight
ca. kg/km
AWG
2x2.5 9.4 48.0 87.0 14
2x4 11.5 77.0 125.0 12
2x6 15.2 116.0 175.0 10
2x10 18.8 192.0 270.0 8
2x16 21.0 308.0 390.0 6
2x25 25.6 480.0 575.0 4
2x35 28.0 672.0 820.0 2
2x50 33.0 960.0 1065.0 1
2x70 36.0 1344.0 1475.0 2/0