  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Power Cables 
PVC Insulated & Sheathed Unarmoured
PVC Insulated & Sheathed Armoured
XLPE Insulated PVC/LSOH Sheathed
LSOH Insulated Conduit Wires
Fire Resistant
Medium Voltage

Power Cables

IEC 12/20(24)kV XLPE Insulated PVC Sheathed Unarmoured Power Cable

Single Core (Unarmoured)

Conductor

Conductor
screen

( mm )

Insulation
thickness

( mm )

Insulation
screen

( mm )

Copper
screen
tape
( mm )

Sheath
thickness

( mm )

Overall
diameter
approx.
( mm )

Cable
weight
approx.
( kg/km )

Insulation
resistance at
15.6∑C (Min.)
( Mohm/km)

Size

(mm)

Shape

Outside
diameter
( mm )

35
50
70
95
120

C.C.
C.C.
C.C.
C.C.
C.C.

6.95
8.05
9.67
11.39
12.33

0.8
0.8
0.8
0.8
0.8

5.5
5.5
5.5
5.5
5.5

0.8
0.8
0.8
1.0
1.0

0.1
0.1
0.1
0.1
0.1

1.8
1.8
1.9
2.0
2.0

27.5
28.7
30.4
32.7
34.3

1007
1165
1426
1771
2064

2200
2000
1800
1600
1500

150
185
240
300
400

C.C.
C.C.
C.C.
C.C.
C.C.

14.24
15.98
18.32
20.65
23.33

0.8
0.8
0.8
0.8
0.8

5.5
5.5
5.5
5.5
5.5

1.0
1.0
1.0
1.0
1.0

0.1
0.1
0.1
0.1
0.1

2.0
2.1
2.2
2.3
2.4

35.8
37.7
40.2
42.7
45.6

2377
2799
3443
4117
5023

1400
1300
1200
1100
1000

500
630

C.C.
C.C.

26.34
30.50

0.8
0.8

5.5
5.5

1.0
1.0

0.1
0.1

2.5
2.6

49.0
53.5

6105
7653

900
800


3 Core (Unarmoured)

Conductor

Conductor
screen

( mm )

Insulation
thickness

( mm )

Insulation
screen

( mm )

Copper
screen
tape
( mm )

Sheath
thickness

( mm )

Overall
diameter
approx.
( mm )

Cable
weight
approx.
( kg/km )

Insulation
resistance at
15.6∑C (Min.)
( Mohm/km)

Size

(mm)

Shape

Outside
diameter
( mm )

35
50
70
95
120

C.C.
C.C.
C.C.
C.C.
C.C.

6.95
8.05
9.67
11.39
12.33

0.8
0.8
0.8
0.8
0.8

5.5
5.5
5.5
5.5
5.5

0.8
0.8
0.8
1.0
1.0

0.1
0.1
0.1
0.1
0.1

2.7
2.8
3.0
3.1
3.2

57.4
60.0
63.8
68.7
72.0

3404
3919
4768
5897
6844

2200
2000
1800
1600
1500

150
185
240
300
400

C.C.
C.C.
C.C.
C.C.
C.C.

14.24
15.98
18.32
20.65
23.33

0.8
0.8
0.8
0.8
0.8

5.5
5.5
5.5
5.5
5.5

1.0
1.0
1.0
1.0
1.0

0.1
0.1
0.1
0.1
0.1

3.3
3.4
3.6
3.8
4.0

75.3
79.3
84.8
90.2
96.4

7853
9211
11275
13441
16339

1400
1300
1200
1100
1000


3 Core (Steel Wire Armoured)

Conductor

Insulation
thickness

( mm )

Copper
screen
tape
( mm )

Inner
sheath
thickness
( mm )

Armour
wire
diameter
( mm )

Outer
sheath
thickness
( mm )

Overall
diameter
approx.
( mm )

Cable
weight
approx.
( kg/km )

Insulation
resistance at
15.6∑C (Min.)
( Mohm/km)

Size

(mm)

Shape

Outside
diameter
( mm )

50
70
95
120
150

C.C.
C.C.
C.C.
C.C.
C.C.

8.05
9.67
11.39
12.33
14.24

5.5
5.5
5.5
5.5
5.5

0.1
0.1
0.1
0.1
0.1

1.6
1.6
1.6
1.6
1.6

2.5
2.5
2.5
2.5
3.15

2.9
3.0
3.1
3.2
3.4

66
70
73
77
82

6960
7980
9170
10300
12500

2000
1800
1600
1500
1400

185
240
300

C.C.
C.C.
C.C.

15.98
18.32
20.65

5.5
5.5
5.5

0.1
0.1
0.1

1.8
1.8
1.8

3.15
3.15
3.15

3.5
3.6
3.8

86
91
97

14100
16500
19000

1300
1200
1100


3 Core(Steel Tape Armoured)

Conductor

Insulation
thickness

( mm )

Copper
screen
tape
( mm )

Inner
sheath
thickness
( mm )

Armour
tape
diameter
( mm )

Outer
sheath
thickness
( mm )

Overall
diameter
approx.
( mm )

Cable
weight
approx.
( kg/km )

Insulation
resistance at
15.6∑C (Min.)
( Mohm/km)

Size

(mm)

Shape

Outside
diameter
( mm )

50
70
95
120
150

C.C.
C.C.
C.C.
C.C.
C.C.

8.05
9.67
11.39
12.33
14.24

5.5
5.5
5.5
5.5
5.5

0.1
0.1
0.1
0.1
0.1

1.6
1.6
1.6
1.6
1.6

0.5
0.5
0.5
0.5
0.5

2.8
2.9
3.0
3.2
3.3

63
67
70
74
78

5370
6240
7340
8350
9530

2000
1800
1600
1500
1400

185
240
300

C.C.
C.C.
C.C.

15.98
18.32
20.65

5.5
5.5
5.5

0.1
0.1
0.1

1.8
1.8
1.8

0.5
0.5
0.8

3.4
3.5
3.7

82
87
94

11000
13100
16500

1300
1200
1100

 

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com