中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
 

Robotics

Extra Flex 10-42
Extra Flex S/H/R/F
Extra Flex Flat/Armour

Robotics

Extra Flex F1 PETP-PUR

Code

Formation

Ext.Diam mm

CU-weight kg/km

F1K3MXC

3x1

7.6

50

F1K4MXC

4x1

8.1

60

F1K7MXC

7x1

10.6

96

F1L4MXC

4x1.5

10.0

83

F1M4MXC

4x2.5

12.0

128

FIV4MXC

4x3.5

13.4

173

FIV7MXC

7x3.5

18.5

290

FIQ7MXC

4x16

22.7

730

FIR4MXC

4x25

27.4

1100

APPLICATION :
Supply of Fanuc brushless motors, Dynamic applications.
TECHNICAL CHARACTERISTICS :
Service Voltage :
1000V power conductors
Test Voltage :
3000V power conductors
Insulation Resistance :
>/= 100 Mohm x km (at 20oC)
Temperature :
Service from -20oC to +80oC, storage from -40oC to + 90oC
Conductor Stranding :
Extra-flexible class 6 acc. Standards VDE 0295 - IEC 228 - CEI 20-29
Primary Insulation :
PETP polyester terephtalate
Conductors Identification :
Black numbered + GR/YE
EMC Shield :
tinned copper braid covering >/= 85%
Taping :
Special tape
Jacket :
Polyurethane PUR abrasion-free colour yellow RAL 1023 or black RAL 9005
Min. Bending Radius :
8 x extendable cable diameter
Translation Speed :
180m/min.
Max. Acceleration :
7m/s2
Reference Standards :
VDE 0472-804 B - IEC 332.1 - CEI 20-35 for flame resistance VDE 0472-803-B for ASTM2 oil resistance CNOMO E.03.40.150N - NFT 46-013 VDE 0472-815 halogen-free version

 

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087