中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables
  Telephone Cables 
CW 1128 Outdoor Telephone Cables
CW 1198 Armoured Outdoor Telephone Cables
CW1308 Indoor Telephone Cables
VDE Standard Indoor Telephone Cables
 

A-02YSOF(L)2Y n x 2 Outdoor Telecommunication Cable According To DIN VDE 0816 Part 1


Reference Standard:
A-02Y(L)2Y Outdoor Telecommunication Cable according to DIN VDE 0816 Part 1
Application: This cable is used in local telephone networks as subscriber cable
Conductor Material: Solid annealed copper conductor
Insulation Material: Foamed PE (02YS)
Laying-up: Star quads in unit stranding
Wrapping: Polyester Tape
Screen Material: Aluminium Foil with copper drain wire
Sheath Material: PE
Sheath Color: Black
Temperature Range: Flexible: -20℃ to +50 ℃ fixed installation: - 40℃ to + 70℃
Operating Voltage: 225V

Electrical Performance:

Conductor Diameter (mm)

Insulation Resistance of per km at 20 o C
Min. (GOhms)

Conductor Resistance per km loop
Max. (Ohms)

0.60

5

130

0.80

5

73.2

Size & Dimensions:

A-02YSOF(L)2Y ... x 2 x 0.8 STIII BD

Part No.

No.of pairs

Outer diameter
( mm )

Cable Weight
( kg/km )

Copper Weight
(kg/km)

CCL-TC-02YSOF6P0.8

6

11.5

150

60

CCL-TC-02YSOF10P08

10

13.0

210

101

CCL-TC-02YSOF20P0.8

20

16.5

360

201

CCL-TC-02YSOF30P0.8

30

19.0

500

302

CCL-TC-02YSOF40P0.8

40

21.0

640

402

CCL-TC-02YSOF50P0.8

50

23.0

775

503

CCL-TC-02YSOF70P0.8

70

27.0

1060

704

CCL-TC-02YSOF100P0.8

100

31.0

1455

1005

CCL-TC-02YSOF150P0.8

150

38.0

2155

1508

 

 

 

 

 

 

 

 

 

 

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489