中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables

  Cable Testing & Fire Resistant Cable

      Introduction to Fire Resistant Cable

At present, in cable industry, Fire Retardant, Low Smoke Halogen Free (LSOH) OR Low Smoke Fume (LSF), Fire Resistant cables are all described as Fire Retardant & Resistant Cables

          Flame Retardant

Fire retardant cables are designed for use in fire situations where the spread of flames along a cable route need to be retarded. Due to relative low cost, fire retardant cables are widely used as fire survival cables. No matter the cables are installed in single wire or in bundles, during a fire, the flame spread will be retarded and the fire will be confined to a small area, thus reducing the fire hazard due to fire propagation.

         Low Smoke & Halogen Free & Fire retardant (LSZH)

LSOH cables are not only characterized by its fire retardant performance but also by its halogen free properties, thus offering low corrosivity and toxicity. During a fire, this cable will emit less smoke and acid gases which may damage the human being and expensive equipment. Compared with normal PVC cable, LSOH cable outperforms by its fire retardant properties, low corrosivity and low smoke emission properties, however, normal PVC cables has better mechanical and electrical properties.

        Low Smoke Fume (LSF)

The low halogen content and low corrosivity of low smoke fume cables lies somewhat in between fire retardant cables and LSOH cables. Low Halogen cable also contains halogen but the content is much less than PVC cables. LSF cable is designed to reduce the spread of fire, toxic gases and smoke during fire. The LSF cable is usually manufactured from flame retardant PVC blended with HCL additive and smoke absorbent. These materials help improve the fire performance of the LSF cables.

       Fire Resistant

Fire resistant cables are designed to maintain circuit integrity of those vital emergency services during the fire. The individual conductors are wrapped with a layer of fire resisting mica/glass tape which prevents phase to phase and phase to earth contact even after the insulation has been burnt away. The fire resistant cables exhibit same performance even under fire with water spray or mechanical shock situation.

    
      
Fire Performance Class

The main concern for the cable in its fire survival properties are its flame spread, smoke characterization and gas toxicity. In American fire standard, the concern lies more on the first two and it differs from the European standard which concerns all these aspects. In USA, it is believed that the fire hazard is mainly due to CO toxic gas emitted and the heat release during the conversion of CO to CO2 during the fire. Therefore, to control the heat release is the most important concern for reducing the fire hazard. However, in European countries, halogen content, the corrosivity of the gases, the smoke density and the toxicity of the gas are equally important factors affecting the safety and survival of human during a fire.

Addison

Marchants Industrial Centre, Mill Lane Laughton, 
Lewes, East Sussex, BN8 6AJ, UK

Tel: 44-207-4195087

Fax: 44-207-8319489

Email: sales@addison-cables.com