中文

  • Home
  • About UsOverview | Mission & Vision | Our Customers | Business Partners | Approvals & Certifications | Milestones
  • ProductsProduct Categories | Business Solutions | Addison & Your Business | Ordering & Testing Information | Warranty
  • Download Product Catalogue | Online Document Viewing
  • Technical Lib Cable Related Standards | Cable Testing & Fire Resistant Cable | Cabling System Library | Material Properties | Cable Glossary
  • Contact
  • Enquiry
  • Sitemap
  • Links Testing Authorities | Testing Equipment Manufacturers | Cable Magazines | Cable Organizations | Addison Corporater Website
  • Airport Cables
  • Alarm & Audio Cables
  • Aluminium Conductor Cables
  • Automotive Cables
  • Belden Equivalent Cables
  • Bus Cables
  • BS standard Cables
    • BS 5308
    • BS 5467
    • BS 6346
    • BS 6724
    • BS 7211
    • BS 8573
  • Coaxial Cables
  • Cable Glands
  • Cables for Oil Industry
  • Control Cables
  • Composite Cables
  • Data Cable
  • Elevator Cables
  • Fiber Optic Cables
  • Fire Resisting Cables
    • Fire Resisting Cable
    • LSZH Flame Retardant Cable
    • PVC Flame Retardant Cable
  • Flexible Cables
  • Heat Detection Cables
  • High Temperature Cables
  • Highway Cables
  • IEC 60502-1
  • Industrial Cables
    • American (UL) Standard
    • Australian Standard (LV)
    • Australian Standard (MV)
    • British Standard
    • French Standard
    • German Standard
    • Harmonized Code
    • Itanlian Standard
    • JIS Standard
    • Spanish Standard
    • Portuguese Standard
  • Instrumentation Cables
  • Lan Cables
  • Offshore Cables
    • NEK606
    • BS6883 & BS7917
    • UKOOA
    • IEC60092
    • JIS
    • Marine & Gas Cables
  • Power Cables
    • Low Voltage Cables
    • Medium Voltage Cables
    • High Voltage Cables
  • Military Cables
  • Mining Cables
  • Motor Connecting Cables
  • Photovoltaic Cables
  • Railway Cables
  • Rolling Stock Cables
  • Robotics
  • Rubber & Crane Cables
  • Security Cables
  • Special Cables
  • Spiral Cables
  • Telephone Cables
  • Thermocouple Cables
  • Windmill Cables

Material Properties

Insulation & Sheath Material Properties In General

Characteristics of High Temp. Insulation and Sheath Materials

Designation

Electrical

VDE initial-code

Abbre-viations

Materials

Density

Break down voltage

Specific volume resistivity

Dielectric-constant

Dielectric loss factor tan δ

g/cm3

KV/mm (20°C)

Ohm·cm 20°C

50 Hz/20°C

10Y

PVDF

Polyvinylidene fluoride

1,7–1,9

25

1014

9–7

1,4 x 10–2

7Y

ETFE

Ethylene-Tetrafluorethylene

1,6–1,8

36

1016

2,6

8 x 10–4

6Y

FEP

Fluorinated ethylene propylene

2,0–2,3

25

1018

2,1

3 x 10–4

5YX

PFA

Perfluoroalkoxypolymeric

2,0–2,3

25

1018

2,1

3 x 10–4

5Y

PTFE

Polytetrafluorethylene

2,0–2,3

20

1018

2,1

3 x 10–4

 

E-CTFE

Ethylene-Chlorotrifluoroethylene

1,67–1,69

39

1015

2.5

9 x 10–3

Designation

Thermic

VDE initial-code

Abbre-viations

Materials

Working temp

 

Melt-temp

 

Oxygen index LOI

Heating value H0

Thermal-conductivity

Corrosive gases in case of fire

Radiation resistance

Perma-nent (°C)

Short time(°C)

+°C

(% O2)

MJ·kg-1

W·K-1·m-1

Mrad

10Y

PVDF

Polyvinylidene fluoride

– 40+135

 

+160

>170

40–45

15

0,17

Hydrofluoric

10

7Y

ETFE

Ethylene-Tetrafluore-thylene

–100+150

 

+180

>265

30–35

14

0,24

Yes

10

6Y

FEP

Fluorinated ethylene propylene

–100+205

 

+230

>225

>95

5

0,26

Yes

1

5YX

PFA

Perfluoroalkoxy-polymeric

–190+260

+280

>290

>95

5

0,21

Yes

0.1

5Y

PTFE

Polytetra-fluorethylene

–190+260

+300

>325

>95

5

0,26

Yes

0,1

 

E-CTFE

Ethylene-Chlorotri-fluoroethylene

–100+140

+170

>242

>60

14

0,14

YES

0.01

Designation

Mechanical

Halogen

VDE initial-code

Abbre-viations

Materials

Tensile strength

Elongation at break

Shore hardness

Water absorbtion

Halogen-free

N/mm2

%

%

 

10Y

PVDF

Polyvinylidene fluoride

50–80

150

75–80 (D)

0,01

No

 

7Y

ETFE

Ethylene-Tetrafluorethylene

40–50

150

70–75 (D)

0,02

6Y

FEP

Fluorinated ethylene propylene

15–25

250

55–60 (D)

0,01

5YX

PFA

Perfluoroalkoxy-polymeric

25–30

250

55–60 (D)

0,01

5Y

PTFE

Polytetra-fluorethylene

80

50

55–60 (D)

0,01

 

E-CTFE

Ethylene-Chlorotri-fluoroethylene

48

200-300

75()D

0.1

Designation

Properties

VDE initial-code

Abbre-viations

Materials

Oxidation resistance

Heat resis-tance

Oil resis-tance

Low-tempe-rature flexibility

Weather, sun resistance

Ozone resis-tance

Abrasion resistance

Flame resis-tance

10Y

PVDF

Polyviny-lidene fluoride

O

O

E

F

E-O

E

E

E

7Y

ETFE

Ethylene-Tetrafluore-thylene

E

E

E

E

E

E

E

G

6Y

FEP

Fluorinated ethylene propylene

O

O

O

O

O

E

E

O

5YX

PFA

Per-fluoroalkoxy-polymeric

E

E

E

E

E

E

G

E

5Y

PTFE

Polytetra-fluorethylene

O

O

E-O

O

O

O

O

E

 

E-CTFE

Ethylene-Chlorotri-fluoroethylene

O

O

O

O

O

E

E

E-O

P = Poor; F= Fair; G = Good; E = Excellent; O = Outstanding

Designation

Properties

VDE initial-code

Abbre-viations

Materials

Water resis-tance

Acid resis-tance

Alkali resis-tance

Aliphatic hydrocarbons resistance (Gasoline, kerosene, etc)

Aromatic

hydrocarbons resistance (Benzol, toluol, etc.)

Halogenated hydrocarbons resistance (Degreaser solvents)

Alcohol resis-tance

10Y

PVDF

Polyviny-lidene fluoride

E

G-E

E

E

G-E

G

E

7Y

ETFE

Ethylene-Tetrafluore-thylene

E

E

E

E

E

E

E

6Y

FEP

Fluorinated ethylene propylene

E

E

E

E

E

E

E

5YX

PFA

Per-fluoroalkoxy-polymeric

E

E

E

E

E

E

E

5Y

PTFE

Polytetra-fluorethylene

E

E

E

E

E

E

E

 

E-CTFE

Ethylene-Chlorotri-fluoroethylene

E

E

E

E

E

E

E

P = Poor; F= Fair; G = Good; E = Excellent; O = Outstanding

 