Início
Quem Somos
Produtos
Baixar
Biblioteca Técnica
Contato
Interrogação
Mapa do Site
Ligações
 

Alarme & cabo Audio & Eletrônico

Belden Equivalente Cabos

Cabos coaxiais

Controle Cabos

Cabos de Fibra Óptica

Cabos Flexíveis

Instrumentação Cabos

Lan Cabos
Cabos de energia
Ferroviária Cabos

Robótica

Material Circulante Cabos
Rubber & Crane Cabos
Cabos de Segurança

Telefone Cabos

Aeroporto Cabos

Cabos Bus

Bucins

Data Cabos

Calor Detecção Cabos
High Temperature Cabos
Highway Cabos
Marine, Petróleo, Gás e Petroquímica Cabos
Cabos Especiais
Cabos espiraloidais
Termopar Cabos
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Thermocouple Cables 

Thermocouple Cables

Part 1 Type 3 PE Insulated Collective Screen Lead SWA PVC Sheathed Thermocouple Cables

Application :
Thermocouple Cables are sensor for measuring temperature, that consists of two dissimilar metals that are joined together at the sensing end. They can be employed as the thermocouple hot junction in addition to serving as the entire wire connection between hot and cold reference junctions.

Types: KX

Conductors: 1.34sqmm Class 5 flexible

Insulation: PE (Polyethylene)

Core identification: See link below

Screen: CAM (Collective aluminium mylar)

Bedding: PE (Polyethylene)

Armour/Protection: LC (Lead alloy)

Bedding: PE (Polyethylene)

Armour/Protection: SWA (Single wire armour)

Sheath/Jacket: PVC (Polyvinyl-Chloride)

Colour: Red

Voltage: 300/500v

Standards: BS4937 International thermocouple reference tables. Extension & compensating cables. Tolerances and identification systems

BS5308 Part 1, Insulated cables, instrumentation, PE

Part 1 Type 3 PE Insulated Collective Screen Lead SWA PVC Sheathed Thermocouple Cables

Size sq
(mm)

Stranding
(mm)

RT of Insulation
(mm)
Diameter over Bedding
(mm)
Diameter of Armour Wire

Diameter over Armour
(mm)

RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

App. Weight
(Kg/Km)

0.5

1/0.8

0.5
5.5
7.7

9.5

1.1

11.7

467

1.3

1/1.29

0.6
6.9
9.1

10.9

1.1

13.1

563

0.5 sqmm (1/0.8mm)

No. of Pairs

Nominal Diameter Laid Up Pairs
(mm)

Nominal Diameter Collective Screen
(mm)
RT of Inner Bedding
(mm)
Diameter over Inner Bedding
(mm)

RT of Lead Alloy Sheath
(mm)

Diameter over Lead Alloy Sheath
(mm)

2

7.5

8.5
0.9
10.3

1.1

12.5

5
10.1
11.1
1.2
13.5
1.1
14.7
10
14.9
15.9
1.2
18.3
1.2
20.7
20
19.9
20.9
1.3
23.5
1.4
26.3
30
23.9
24.9
1.5
27.9
1.5
30.9

50

31.1

32.1
2.0
36.1

1.8

39.7


No. of Pairs

RT of Outer Bedding
(mm)

Diameter of Outer Bedding
(mm)
Diameter of Armour Wire
(mm)
Diameter over Armour
(mm)
RT of Outer Sheath
(mm)

Nominal Overall Diameter
(mm)

Weight
(Kg/Km)

2

0.8

14.1
1.25
16.6
1.5

19.6

1140

5
0.8
17.3
1.25
19.8
1.6
23.0
1450
10
1.0
22.7
1.6
25.9
1.7
29.3
2300
20
1.2
28.7
2.0
32.7
1.9
36.5
3580
30
1.2
33.3
2.0
37.3
2.0
41.3
4470

50

1.4

42.5
2.5
47.5
2.3

52.1

6780

Operating Temperature: Max 105°C, Min -30°C, Min bending 0°C

Min bending radius: 12 X Overall Diameter

Conductor Dimensions

Size & Stranding: 0.5 sqmm (1/0.8mm)