Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL, GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Rolling Stock Cables

Rolling Stock Cables

   RSE/STD/024 PART 6

      RSE/STD/024 Part 6 Rolling Stock Cable

Voltage

Cable Type

Construction

Number

of Cores

Cross Sectional
Areas/Stranding Class

Design Standard

Fire Standard

300/500V

Single Core, unsheathed

CU/EM 104 EVA

1C

0.5mm2-4mm2, 19/37 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V

Single Core, unsheathed

CU/EM 104 EVA

1C

0.5mm2-10mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V

Single Core, unsheathed

CU/EM 104 EVA

1C

1.0mm2-6.0mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V

Multicore, with jacketType Ⅶ

CU/EI 104 EPR/EM 104 EVA

12/42C

1.0mm2-1.5mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V

Multicore, with jacket

Type Ⅻ

CU/EI 104 EPR/EM 104 EVA

12/42C

1.0mm2-1.5mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V

Multipair, with jacket screened

CU/EI 104 EPR/CUTO/EM 104 EVA

1,2,3 Prs

0.5mm2-1.0mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V

Multipair, with jacket screened

CU/EI 104 EPR/CUTO/EM 104 EVA

1,2,3,4 Prs

0.5mm2-1.0mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V

Single Core, unsheathed

CU/EM 104 EVA

1C

0.5mm2-4mm2, 19/37 strand

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V

Single Core, unsheathed

CU/EM 104 EVA

1C

0.75mm2-300mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V

Single Core, unsheathed

CU/EM 104 EVA

1C

50mm2-185mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V

Multicore, with jacket

CU/EI 104 EPR/EM 104 EVA

10/20C

2.5mm2-4mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

600/1000V

Singlepair, with jacket screened

CU/EI 104 EPR/CUTO/EM 104 EVA

1 Prs

1.0mm2, Class 5 stranding

RSE/STD/024 Part 6

IEC 332-3C

IEC 754 IEC1034

300/500V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅳ Cable, unsheathed  

Cross- sectional Area

0.5mm2-4mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

19/37 AWG stranding

Insulation

Cross linked EPR rubber type EI 107, Reduced Wall

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

singlecore

0.5

19/0.18

300/500

1.34

5.4

singlecore

0.75

37/0.16

300/500

1.56

8.0

singlecore

1.0

37/0.18

300/500

1.69

9.9

singlecore

1.5

37/0.23

300/500

2.07

15.7

singlecore

2.5

37/0.3

300/500

2.66

26.8

singlecore

4.0

37/0.37

300/500

3.32

41.1

300/500V Singlecore RSE/STD/024 Part 6 Rolling Stock Type Ⅴ Cable, unsheathed  

Cross- sectional Area

0.5mm2-10mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Standard Wall

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

singlecore

0.5

16/0.2

300/500

2.32

9.6

singlecore

0.75

74/0.2

300/500

2.53

12.4

singlecore

1.0

32/0.2

300/500

2.71

15.1

singlecore

1.5

30/0.25

300/500

3.23

21.9

singlecore

2.5

50/0.25

300/500

3.7

33.5

singlecore

4.0

56/0.3

300/500

4.5

50.0

singlecore

6.0

84/0.3

300/500

5.09

74.6

singlecore

10.0

80/0.4

300/500

6.3

122.6

300/500V Single Core RSE/STD/024 Part 6 Rolling Stock Type VI screened Cable 

Cross- sectional Area

1.0mm2-6.0mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Standard Wall

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

Singlecore

1.0

32/0.2

300/500

3.3

19.2

Singlecore

1.5

30/0.25

300/500

3.7

26.3

Singlecore

2.5

50/0.25

300/500

4.16

37.8

Singlecore

4.0

56/0.3

300/500

4.95

56.6

Singlecore

6.0

84/0.3

300/500

5.55

80.4

300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type Ⅶ Cable, with jacket  

Cross- sectional Area

1.0mm2-1.5mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of cores

12-42

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Standard Wall

Jacket

Cross linked EVA rubber type EM 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

 

 

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

12 Core

1.0

32/0.2

30/50

20.25

309.0

42 Core

1.5

30/0.25

30/50

38.35

1661.0

300/500V Multicore RSE/STD/024 Part 6 Rolling Stock Type VIII Cable, with jacket  

Cross- sectional Area

1.0mm2-1.5mm2

Voltage rating

300/500V

Conductor

Flexible Stranded Tinned Copper

Number of cores

12-42

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107,Standard Wall

Jacket

Cross linked EVA rubber type EMI 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

12 Core

1.0

32/0.2

300/500

20.3

309.0

42 Core

1.5

30/0.25

300/500

38.4

1661.0