Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL,GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Rolling Stock Cables

Rolling Stock Cables

   RSE/STD/024 PART 6

      RSE/STD/024 Part 6 Rolling Stock Cable

600/1000V Singlecore RSE/STD/024 Part 6 Rolling StockType Ⅲ Cable ,unsheathed

Cross- sectional Area

50mm2-185mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Enhanced Wall

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter (mm)

Nominal Weight (kg/km)

singlecore

50.0

396/0.4

600/1000

16.45

667.0

singlecore

70.0

360/0.5

600/1000

18.35

873.0

singlecore

95.0

475/0.6

600/1000

19.5

1108.0

singlecore

150.0

756/0.5

600/1000

24.1

1663.0

singlecore

185.0

925/0.5

600/1000

26.5

2024.0

600/1000V Multicore RSE/STD/024 Part 6 Rolling Stock Type Ⅵ Cable, with jacket

Cross- sectional Area

2.5mm2-4mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

10-20

Conductor class

IEC 60228 Class 5

Insulation

Cross linked EPR rubber type EI 107, Standard Wall

Jacket

Cross linked EVA rubber type EM 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Cores

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight

(kg/km)

10 Core

2.5

50/0.25

600/1000

28.1

1148.0

20 Core

4.0

56/0.3

600/1000

42.7

2421.0

 600/1000V Singlepair RSE/STD/024 Part 6 Rolling Stock Type Ⅹscreened Cable, with jacket 

Cross- sectional Area

1.0mm2

Voltage rating

600/1000V

Conductor

Flexible Stranded Tinned Copper

Number of cores

1

Conductor class

37 AWG stranding

Insulation

Cross linked EPR rubber type EI 107, Reduced Wall

Screen

Copper Braid Screen

Jacket

Cross linked EVA rubber type EM 104

Fire standard

IEC 332-3C,IEC754;IEC1034-1/2


No. of Pairs

Cross Sectional Area

(mm2)

Number and Nominal Diameter of Strands

(mm)

Voltage Rating

(V)

Nominal Overall
Diameter

(mm)

Nominal Weight (kg/km)

1 Pair

1.0

37/0.18

600/1000

7.3

76.4

                                                                        1       2       3