Início
Quem Somos
Produtos
Baixar
Biblioteca Técnica
Contato
Interrogação
Mapa do Site
Ligações
 

Alarme & cabo Audio & Eletrônico

Belden Equivalente Cabos

Cabos coaxiais

Controle Cabos

Cabos de Fibra Óptica

Cabos Flexíveis

Instrumentação Cabos

Lan Cabos
Cabos de energia
Ferroviária Cabos

Robótica

Material Circulante Cabos
Rubber & Crane Cabos
Cabos de Segurança

Telefone Cabos

Aeroporto Cabos

Cabos Bus

Bucins

Data Cabos

Calor Detecção Cabos
High Temperature Cabos
Highway Cabos
Marine, Petróleo, Gás e Petroquímica Cabos
Cabos Especiais
Cabos espiraloidais
Termopar Cabos
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Bus Cables

Bus Cables

ASI Cables

Application: The ASI is the field bus system that transmits both data and power in one single cable. With fast contacting in penetration technique, it can largely reduce the possibility of errors in cabling. Different jacket can provide protection against oils, grease, and refrigerant lubricants.

ASI EPDM Cables

ASI PUR Cables

ASI PVC Cables

 

ASI EPDM Cables

Conductor: Tinned Copper

Insulation: Rubber Compound

Conductor Colour: Blue, Brown

Sheath/Jacket: EPDM

Colour: Yellow / Black

Operating temperature: - 40 °C to +85 °C

Standards: ASI Standard

Size (Type)

Conductor Resistance
Insulation Resistance
Nominal Voltage
Testing Voltage
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 1.5mm2 (Yellow)

13.7 Ohm/km
1.00 GOhm x km Min.
32 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 70.0 kg/km

2 X 1.5mm2 (Black)

13.7 Ohm/km
1.00 GOhm x km Min.
48 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 70.0 kg/km

 

ASI PUR Cables

Conductor: Tinned Copper

Insulation: Rubber Compound

Conductor Colour: Blue, Brown

Sheath/Jacket: PUR

Colour: Yellow / Black

Operating temperature: - 40 °C to +85 °C

Standards: ASI Standard

Size (Type)

Conductor Resistance
Insulation Resistance
Nominal Voltage
Testing Voltage
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 1.5mm2 (Yellow)

13.7 Ohm/km
1.00 GOhm x km Min.
32 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 64.0 kg/km

2 X 1.5mm2 (Black)

13.7 Ohm/km
1.00 GOhm x km Min.
48 V
1.0 kV @ 15 min.
30.0 mm
0.96 MJ/m
Approx. 64.0 kg/km

 

ASI PVC Cable

Conductor: Tinned Copper

Insulation: TPE

Conductor Colour: Blue, Brown

Sheath/Jacket: PVC

Colour: Yellow / Black

Operating temperature: - 40 °C to +105 °C

Standards: ASI Standard

UL Style: CMG 90°C or CL2

CSA Standard: CSA FT4

Size (Type)

Conductor Resistance
Insulation Resistance
Nominal Voltage
Testing Voltage
Min. Bending Radius
Caloric Load, approx. value
Weight

2 X 1.5mm2 (Yellow)

13.7 Ohm/km
1.00 GOhm x km Min.
32 V
1.0 kV @ 15 min.
24.0 mm
0.66 MJ/m
Approx. 70.0 kg/km

2 X 1.5mm2 (Black)

13.7 Ohm/km
1.00 GOhm x km Min.
48 V
1.0 kV @ 15 min.
24.0 mm
0.65 MJ/m
Approx. 70.0 kg/km